Your browser doesn't support javascript.
loading
Quantifying Short-Chain Chlorinated Paraffin Congener Groups.
Yuan, Bo; Bogdal, Christian; Berger, Urs; MacLeod, Matthew; Gebbink, Wouter A; Alsberg, Tomas; de Wit, Cynthia A.
Afiliação
  • Yuan B; Department of Environmental Science and Analytical Chemistry, Stockholm University , Svante Arrhenius väg 8, SE-10691 Stockholm, Sweden.
  • Bogdal C; Institute for Chemical and Bioengineering, Swiss Federal Institute of Technology, ETH Zurich , Vladimir-Prelog-Weg 1, CH-8093 Zürich, Switzerland.
  • Berger U; Department Analytical Chemistry, Helmholtz Centre for Environmental Research-UFZ , Permoserstraße 15, DE-04318, Leipzig, Germany.
  • MacLeod M; Department of Environmental Science and Analytical Chemistry, Stockholm University , Svante Arrhenius väg 8, SE-10691 Stockholm, Sweden.
  • Gebbink WA; RIKILT, Wageningen University & Research , P.O. Box 230, Akkermaalsbos 2, NL-6708 AE, Wageningen, Netherlands.
  • Alsberg T; Department of Environmental Science and Analytical Chemistry, Stockholm University , Svante Arrhenius väg 8, SE-10691 Stockholm, Sweden.
  • de Wit CA; Department of Environmental Science and Analytical Chemistry, Stockholm University , Svante Arrhenius väg 8, SE-10691 Stockholm, Sweden.
Environ Sci Technol ; 51(18): 10633-10641, 2017 Sep 19.
Article em En | MEDLINE | ID: mdl-28813149
ABSTRACT
Accurate quantification of short-chain chlorinated paraffins (SCCPs) poses an exceptional challenge to analytical chemists. SCCPs are complex mixtures of chlorinated alkanes with variable chain length and chlorination level; congeners with a fixed chain length (n) and number of chlorines (m) are referred to as a "congener group" CnClm. Recently, we resolved individual CnClm by mathematically deconvolving soft ionization high-resolution mass spectra of SCCP mixtures. Here we extend the method to quantifying CnClm by introducing CnClm specific response factors (RFs) that are calculated from 17 SCCP chain-length standards with a single carbon chain length and variable chlorination level. The signal pattern of each standard is measured on APCI-QTOF-MS. RFs of each CnClm are obtained by pairwise optimization of the normal distribution's fit to the signal patterns of the 17 chain-length standards. The method was verified by quantifying SCCP technical mixtures and spiked environmental samples with accuracies of 82-123% and 76-109%, respectively. The absolute differences between calculated and manufacturer-reported chlorination degrees were -0.9 to 1.0%Cl for SCCP mixtures of 49-71%Cl. The quantification method has been replicated with ECNI magnetic sector MS and ECNI-Q-Orbitrap-MS. CnClm concentrations determined with the three instruments were highly correlated (R2 > 0.90) with each other.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parafina / Monitoramento Ambiental Idioma: En Revista: Environ Sci Technol Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parafina / Monitoramento Ambiental Idioma: En Revista: Environ Sci Technol Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suécia