Correction of hyperopia with astigmatism following radial keratotomy with daily disposable plus spherical contact lens: a case report.
Chen, Yun-Wen; Lee, Jiahn-Shing; Hou, Chiun-Ho; Lin, Ken-Kuo.
Afiliação
  • Chen YW; Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan.
  • Lee JS; Department of Ophthalmology, LinKo Chang Gung Memorial Hospital, Chang Gung University College of Medicine, No.5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan.
  • Hou CH; Department of Ophthalmology, LinKo Chang Gung Memorial Hospital, Chang Gung University College of Medicine, No.5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan.
  • Lin KK; Department of Ophthalmology, LinKo Chang Gung Memorial Hospital, Chang Gung University College of Medicine, No.5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan. d12093@cgmh.org.tw.
Int Ophthalmol ; 38(5): 2199-2204, 2018 Oct.
Article em En | MEDLINE | ID: mdl-28856508
PURPOSE: To report the refractive correction in a case of hyperopia and astigmatism following radial keratotomy. METHODS: A case report. RESULTS: A 47-year-old woman, who had undergone refractive surgery for radial keratotomy in both eyes 22 years before the present study, presented to our clinic with blurred vision. Her best corrected visual acuity, with spectacle correction of +3.50 DS/-1.50 DCX130° in the right eye and +3.75 DS/-1.50 DCX80° in the left eye, was 0.2 logMAR and 0.3 logMAR, respectively. Her keratometric readings were 35.75 D/36.75 D at 74° and 35.25 D/36.25 D at 61°, respectively. Prompted by intolerance to glasses, the patient requested for contact lenses. First, we applied a rigid, gas-permeable contact lens. However, we noted poor fitting due to central corneal flattening. Subsequently, we applied a conventional plus spherical soft contact lens (PSSCL), which is thick in the center and can therefore correct hyperopia and low-grade astigmatism simultaneously. The conventional PSSCL showed slightly inferior decentration, with good movement, and the patient was satisfied with it. After ascertaining the patient's living habits, we decided that a daily disposable soft contact lens would most meet her needs. The final prescription was a daily disposable PSSCL; the patient was satisfied with her corrected visual acuity of 0.0 logMAR in the right eye and 0.0 logMAR in left eye. Her daily disposable PSSCL-corrected visual acuity was stable during the 10-month follow-up. CONCLUSION: For patients displaying hyperopia with astigmatism following radial keratotomy, the PSSCL may confer better corrected visual acuity and acceptability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Astigmatismo / Ceratotomia Radial / Lentes de Contato Hidrofílicas / Córnea / Equipamentos Descartáveis / Hiperopia Tipo de estudo: Etiology_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Astigmatismo / Ceratotomia Radial / Lentes de Contato Hidrofílicas / Córnea / Equipamentos Descartáveis / Hiperopia Tipo de estudo: Etiology_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Taiwan