Your browser doesn't support javascript.
loading
Methods for the field evaluation of quantitative G6PD diagnostics: a review.
Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N.
Afiliação
  • Ley B; Global and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia. benedikt.ley@menzies.edu.au.
  • Bancone G; Shoklo Malaria Research Unit, Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Mae Sot, Thailand.
  • von Seidlein L; Centre for Tropical Medicine and Global Health, Nuffield Department of Clinical Medicine, University of Oxford, Oxford, UK.
  • Thriemer K; Mahidol-Oxford Tropical Medicine Research Unit (MORU), Bangkok, Thailand.
  • Richards JS; Global and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia.
  • Domingo GJ; Malaria Elimination Program, Burnet Institute, Melbourne, VIC, Australia.
  • Price RN; Department of Medicine, University of Melbourne, Parkville, VIC, Australia.
Malar J ; 16(1): 361, 2017 09 11.
Article em En | MEDLINE | ID: mdl-28893237
ABSTRACT
Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Programas de Rastreamento / Sistemas Automatizados de Assistência Junto ao Leito / Glucosefosfato Desidrogenase / Deficiência de Glucosefosfato Desidrogenase Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Programas de Rastreamento / Sistemas Automatizados de Assistência Junto ao Leito / Glucosefosfato Desidrogenase / Deficiência de Glucosefosfato Desidrogenase Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália