Your browser doesn't support javascript.
loading
A complex case of pacemaker lead endocarditis. / Um caso complexo de endocardite de sondas de pacemaker.
Guedes, Henrique; Pereira, Adriana; Pontes Dos Santos, Rui; Marques, Leonor; Moreno, Nuno; Castro, Alexandra; Cunha E Sousa, Rui; Andrade, Aurora; Pinto, Paula.
Afiliação
  • Guedes H; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal. Electronic address: henrique.jp.guedes@gmail.com.
  • Pereira A; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Pontes Dos Santos R; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Marques L; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Moreno N; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Castro A; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Cunha E Sousa R; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Andrade A; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
  • Pinto P; Serviço de Cardiologia, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
Rev Port Cardiol ; 36(10): 775.e1-775.e5, 2017 Oct.
Article em En, Pt | MEDLINE | ID: mdl-29037831
ABSTRACT
Pacemaker lead endocarditis is an uncommon complication after pacemaker implantation, but is associated with high rates of morbidity and mortality. The authors describe the case of a 68-year-old woman with a double-chamber pacemaker since 2007, admitted to an internal medicine department for spondylodiscitis and Staphylococcus aureus bacteremia. During hospitalization, she had an episode of syncope; the 12-lead electrocardiogram showed pacemaker malfunction with ventricular undersensing and loss of capture. A transesophageal echocardiogram showed images compatible with vegetations on the pacemaker leads. After antimicrobial therapy, the patient developed acute renal failure with subsequent multiple organ failure and death. A high index of clinical suspicion is required for early diagnosis and appropriate treatment of cardiac device-related infective endocarditis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Infecções Estafilocócicas / Infecções Relacionadas à Prótese / Endocardite Bacteriana Tipo de estudo: Screening_studies Limite: Aged / Female / Humans Idioma: En / Pt Revista: Rev Port Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Infecções Estafilocócicas / Infecções Relacionadas à Prótese / Endocardite Bacteriana Tipo de estudo: Screening_studies Limite: Aged / Female / Humans Idioma: En / Pt Revista: Rev Port Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2017 Tipo de documento: Article