Your browser doesn't support javascript.
loading
Selection of appropriate endotracheal tube size using thoracic radiography in Beagle dogs.
Shin, Chi Won; Son, Won-Gyun; Jang, Min; Kim, Hyunseok; Han, Hyungjoo; Cha, Jeesoo; Lee, Inhyung.
Afiliação
  • Shin CW; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.
  • Son WG; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.
  • Jang M; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea; Ian Animal Diagnostic Imaging Center, Seoul, Republic of Korea.
  • Kim H; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.
  • Han H; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.
  • Cha J; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.
  • Lee I; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea. Electronic address: inhyunglee@snu.ac.kr.
Vet Anaesth Analg ; 45(1): 13-21, 2018 Jan.
Article em En | MEDLINE | ID: mdl-29246712
ABSTRACT

OBJECTIVE:

To determine the optimal endotracheal tube size in Beagle dogs using thoracic radiography. STUDY

DESIGN:

Prospective, randomized, crossover experimental study. ANIMALS A total of eight healthy adult Beagle dogs.

METHODS:

Lateral thoracic radiographs were used to measure the internal tracheal diameter at the thoracic inlet. This measurement was multiplied by 60, 70 and 80% to determine the outer diameter of the endotracheal tube for each dog. In each treatment, medetomidine (5 µg kg-1) was administered intravenously (IV) for premedication. Anesthesia was induced with alfaxalone (2 mg kg-1) IV and maintained with isoflurane. After induction of anesthesia, the resistance to passage of the endotracheal tube through the trachea was scored by a single anesthesiologist. Air leak pressures (Pleak) were measured at intracuff pressures (Pcuff) of 20 and 25 mmHg (27 and 34 cmH2O). The results were analyzed using Friedman tests and repeated measures anova.

RESULTS:

There were statistically significant increases in resistance as the endotracheal tube size increased (p = 0.003). When Pcuff was 20 mmHg, mean Pleak for the 60, 70 and 80% treatments were 9.7 ± 6.7, 16.2 ± 4.2 and 17.4 ± 3.9 cmH2O, respectively, but no significant differences were found. When Pcuff was 25 mmHg, mean Pleak for the 60, 70 and 80% treatments were 10.6 ± 8.5, 19.7 ± 4.9 and 20.8 ± 3.6 cmH2O, respectively, and statistically significant increases were found between treatments 60 and 70% (p = 0.011) and between treatments 60 and 80% (p = 0.020). Three dogs in the 80% treatment had bloody mucus on the endotracheal tube cuff after extubation. CONCLUSIONS AND CLINICAL RELEVANCE Results based on resistance to insertion of the endotracheal tube and the ability to achieve an air-tight seal suggest that an appropriately sized endotracheal tube for Beagle dogs is 70% of the internal tracheal diameter measured on thoracic radiography.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Cães / Intubação Intratraqueal Tipo de estudo: Observational_studies Limite: Animals Idioma: En Revista: Vet Anaesth Analg Assunto da revista: ANESTESIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Cães / Intubação Intratraqueal Tipo de estudo: Observational_studies Limite: Animals Idioma: En Revista: Vet Anaesth Analg Assunto da revista: ANESTESIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article