Determination of vitamins K1 , MK-4, and MK-7 in human serum of postmenopausal women by HPLC with fluorescence detection.
Klapkova, Eva; Cepova, Jana; Dunovska, Katerina; Prusa, Richard.
Afiliação
  • Klapkova E; Department of Medical Chemistry and Clinical Biochemistry, Charles University, 2nd Faculty of Medicine and University Hospital Motol, Prague, Czech Republic.
  • Cepova J; Department of Medical Chemistry and Clinical Biochemistry, Charles University, 2nd Faculty of Medicine and University Hospital Motol, Prague, Czech Republic.
  • Dunovska K; Department of Medical Chemistry and Clinical Biochemistry, Charles University, 2nd Faculty of Medicine and University Hospital Motol, Prague, Czech Republic.
  • Prusa R; Department of Medical Chemistry and Clinical Biochemistry, Charles University, 2nd Faculty of Medicine and University Hospital Motol, Prague, Czech Republic.
J Clin Lab Anal ; 32(5): e22381, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29333616
ABSTRACT

BACKGROUND:

New high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K1 and two forms of vitamin K2 (MK-4 and MK-7) in human serum, and the levels of vitamin K were determined in 350 samples of postmenopausal women.

METHODS:

Vitamin K was determined by HPLC with fluorescence detection after postcolumn zinc reduction. The detection was performed at 246 nm (excitation) and 430 nm (emission). The internal standard and 2 mL of ethanol were added to 500 µL of serum. The mixture was extracted with 4 mL of hexane, and solid phase extraction was then used.

RESULTS:

The HLPC method was fully validated. The intra- and interday accuracy and precision were evaluated on two QC samples by multiple analysis, and CV were less than 10%. The limit of quantification for MK-4 was found at 0.04 ng/mL, for K1 0.03 ng/mL, and for MK-7 0.03 ng/mL. The mean recoveries of the corresponding compounds were 98%-110%. Serum levels of MK-4, K1 , and MK-7 in postmenopausal women with osteoporosis were 0.890 ± 0.291 ng/mL, 0.433 ± 0.394 ng/mL, and 1.002 ± 1.020 ng/mL, respectively (mean ± SD). Serum levels of MK-4, K1 , and MK-7 in postmenopausal women without osteoporosis were 0.825 ± 0.266 ng/mL, 0.493 ± 0.399 ng/mL, and 1.186 ± 1.076 ng/mL, respectively (mean ± SD).

CONCLUSION:

New HPLC method for the determination of vitamins K1 , MK-4, and MK-7 in serum was evaluated and validated. This method is highly specific and sensitive with the low limit of quantification.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina K 1 / Cromatografia Líquida de Alta Pressão / Pós-Menopausa / Vitamina K 2 / Fluorescência Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: República Tcheca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina K 1 / Cromatografia Líquida de Alta Pressão / Pós-Menopausa / Vitamina K 2 / Fluorescência Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: República Tcheca