Your browser doesn't support javascript.
loading
Truly anatomic coracoclavicular ligament reconstruction with 2 Endobutton devices for acute Rockwood type V acromioclavicular joint dislocations.
Xue, Cheng; Song, Li-Jun; Zhang, Hao; Tang, Guo-Long; Li, Xiang; Fang, Jia-Hu.
Afiliação
  • Xue C; Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China.
  • Song LJ; Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China.
  • Zhang H; Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China.
  • Tang GL; Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China.
  • Li X; Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China. Electronic address: lixiangjsph@163.com.
  • Fang JH; Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China. Electronic address: fjh4508@163.com.
J Shoulder Elbow Surg ; 27(6): e196-e202, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29352695
ABSTRACT

BACKGROUND:

Truly anatomic coracoclavicular ligament reconstruction (TACCR) according to the original insertions is a creative new method for the treatment of severe acromioclavicular separation. This research analyzed the clinical and radiologic results of TACCR in 25 patients with at least 2-year follow-up.

METHODS:

The study enrolled 25 patients with Rockwood type V acromioclavicular joint dislocations who underwent TACCR using 2 Endobutton (Smith & Nephew Inc., Andover, MA, USA) devices from May 2013 to October 2015. Patients were assessed with clinical and radiologic follow-up at 3, 6, 12, 18, and 24 months postoperatively. The clinical assessments consisted of the visual analog scale and the Constant score. The radiographic evaluations were performed by measurements of the coracoclavicular distance.

RESULTS:

The mean follow-up was 34 ± 6.8 months (range, 24-48 months). The visual analog scale and Constant scores revealed significant advancements from 5 ± 0.9 (range, 4-7) and 45 ± 5.6 (range, 30-54) scores preoperatively to 0 ± 0.5 (range, 0-2) and 95 ± 2.9 (range, 91-98) scores at 24 months postoperatively, respectively. The coracoclavicular distance significantly decreased from 23 ± 5.4 mm (range, 16-34 mm) preoperatively to 8 ± 0.9 mm (range, 7-10 mm) at the final follow-up.

CONCLUSIONS:

TACCR represents a safe, reliable and creative surgical technique that yields good to excellent clinical and radiologic outcomes in the treatment of severe acromioclavicular separation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Acromioclavicular / Procedimentos de Cirurgia Plástica / Luxações Articulares / Ligamentos Articulares Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Acromioclavicular / Procedimentos de Cirurgia Plástica / Luxações Articulares / Ligamentos Articulares Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China