Your browser doesn't support javascript.
loading
Sport and exercise medicine consultants are reliable in assessing tendon neovascularity using ultrasound Doppler.
Watson, James; Barker-Davies, Robert M; Bennett, Alexander N; Fong, Daniel T P; Wheeler, Patrick C; Lewis, Mark; Ranson, Craig.
Afiliação
  • Watson J; Academic Department of Military Rehabilitation, Defence Medical Rehabilitation Centre, London, UK.
  • Barker-Davies RM; Cardiff School of Sport, Cardiff Metropolitan University, Cardiff, UK.
  • Bennett AN; Academic Department of Military Rehabilitation, Defence Medical Rehabilitation Centre, London, UK.
  • Fong DTP; National Centre for Sport and Exercise Medicine, School of Sport Exercise and Health Sciences, Loughborough University, London, UK.
  • Wheeler PC; Academic Department of Military Rehabilitation, Defence Medical Rehabilitation Centre, London, UK.
  • Lewis M; Faculty of Medicine, National Heart and Lung Institute, Imperial College, London, UK.
  • Ranson C; National Centre for Sport and Exercise Medicine, School of Sport Exercise and Health Sciences, Loughborough University, London, UK.
BMJ Open Sport Exerc Med ; 4(1): e000298, 2018.
Article em En | MEDLINE | ID: mdl-29527321
ABSTRACT

OBJECTIVE:

Several lower limb tendinopathy treatment modalities involve identification of pathological paratendinous or intratendinous neovascularisation to target proposed co-location of painful neoneuralisation. The ability to reliably locate and assess the degree of neovascularity is therefore clinically important. The Modified Ohberg Score (MOS) is frequently used to determine degree of neovascularity, but reliability has yet to be established among Sport and Exercise Medicine (SEM) consultants. This study aims to determine inter-rater and intra-rater reliability of an SEM consultant cohort when assessing neovascularity using the 5-point MOS.

METHOD:

Eleven participants (7 male and 4 female) provided 16 symptomatic Achilles and patella tendons. These were sequentially examined using power Doppler (PD) enabled ultrasound (US) imaging by 6 SEM consultants who rated neovascular changes seen using the MOS. Representative digital scan images were saved for rescoring 3 weeks later. Inter-rater and intra-rater reliability of the MOS was examined using intraclass correlation coefficient (ICC) and Kappa Agreement scores.

RESULTS:

Neovascular changes were reported in 65.6% of 96 scans undertaken. ICC for inter-rater reliability was 0.86 and Fleiss Kappa 0.52. ICC for intra-rater reliability was 0.95 and Weighted Kappa 0.91.

CONCLUSIONS:

Neovascular changes were present in two-thirds of symptomatic tendons. Excellent SEM consultant inter-rater and intra-rater reliability was demonstrated. These findings support the use of PD-enabled US to assess neovascularity by appropriately experienced SEM consultants. Furthermore, future interventional research using a similarly experienced SEM consultant cohort can be undertaken with assurance that assessment of neovascularity will be reliable.