Your browser doesn't support javascript.
loading
Sensitive paper-based analytical device for fast colorimetric detection of nitrite with smartphone.
Zhang, Xiu-Xiu; Song, Yi-Zhen; Fang, Fang; Wu, Zhi-Yong.
Afiliação
  • Zhang XX; Research Center for Analytical Sciences, Chemistry Department College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China.
  • Song YZ; Research Center for Analytical Sciences, Chemistry Department College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China.
  • Fang F; Research Center for Analytical Sciences, Chemistry Department College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China.
  • Wu ZY; Research Center for Analytical Sciences, Chemistry Department College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China. zywu@mail.neu.edu.cn.
Anal Bioanal Chem ; 410(11): 2665-2669, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29556736
On-site rapid monitoring of nitrite as an assessment indicator of the environment, food, and physiological systems has drawn extensive attention. Here, electrokinetic stacking (ES) was combined with colorimetric reaction on a paper-based device (PAD) to achieve colorless nitrite detection with smartphone. In this paper, nitrite was stacked on the paper fluidic channel as a narrow band by electrokinetic stacking. Then, Griess reagent was introduced to visualize the stacking band. Under optimal conditions, the sensitivity of nitrite was 160-fold increased within 5 min. A linear response in the range of 0.075 to 1.0 µg mL-1 (R2 = 0.99) and a limit of detection (LOD) of 73 ng mL-1 (0.86 µM) were obtained. The LOD was 10 times lower than the reported PAD, and close to that achieved by a desktop spectrophotometer. The applicability was demonstrated by nitrite detection from saliva and water with good selectivity, adding 100 times more concentrated co-ions. High recovery (91.0~108.7%) and reasonable intra-day and inter-day reproducibility (RSD < 9%) were obtained. This work shows that the sensitivity of colorless analyte detection-based colorimetric reaction can be effectively enhanced by integration of ES on a PAD. Graphical abstract Schematic of the experimental setups (left) and the corresponding images (right) of the actual portable device.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Saliva / Poluentes Químicos da Água / Água / Colorimetria / Nitritos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Saliva / Poluentes Químicos da Água / Água / Colorimetria / Nitritos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China