Your browser doesn't support javascript.
loading
High-speed tomography under extreme conditions at the PSICHE beamline of the SOLEIL Synchrotron.
Boulard, E; King, A; Guignot, N; Deslandes, J P; Le Godec, Y; Perrillat, J P; Clark, A; Morard, G; Itié, J P.
Afiliação
  • Boulard E; Synchrotron SOLEIL, L'Orme des Merisiers, 91192 St Aubin, France.
  • King A; Synchrotron SOLEIL, L'Orme des Merisiers, 91192 St Aubin, France.
  • Guignot N; Synchrotron SOLEIL, L'Orme des Merisiers, 91192 St Aubin, France.
  • Deslandes JP; Synchrotron SOLEIL, L'Orme des Merisiers, 91192 St Aubin, France.
  • Le Godec Y; Sorbonne Université, Muséum National d'Histoire Naturelle, UMR CNRS 7590, IRD, Institut de Minéralogie, Physique des Matériaux et Cosmochimie - IMPMC, 4 Place Jussieu, 75005 Paris, France.
  • Perrillat JP; Laboratoire de Géologie de Lyon, UMR CNRS 5276, Université Claude Bernard Lyon 1, ENS de Lyon, 69622 Villeurbanne, France.
  • Clark A; Sorbonne Université, Muséum National d'Histoire Naturelle, UMR CNRS 7590, IRD, Institut de Minéralogie, Physique des Matériaux et Cosmochimie - IMPMC, 4 Place Jussieu, 75005 Paris, France.
  • Morard G; Sorbonne Université, Muséum National d'Histoire Naturelle, UMR CNRS 7590, IRD, Institut de Minéralogie, Physique des Matériaux et Cosmochimie - IMPMC, 4 Place Jussieu, 75005 Paris, France.
  • Itié JP; Synchrotron SOLEIL, L'Orme des Merisiers, 91192 St Aubin, France.
J Synchrotron Radiat ; 25(Pt 3): 818-825, 2018 May 01.
Article em En | MEDLINE | ID: mdl-29714193
ABSTRACT
In situ microtomography at high pressure and temperature has developed rapidly in the last decade, driven by the development of new high-pressure apparatus. It is now routinely possible to characterize material under high pressure with acquisition times for tomograms of the order of tens of minutes. Here, advantage was taken of the possibility to combine the use of a pink beam projected through a standard Paris-Edinburgh press in order to demonstrate the possibility to perform high-speed synchrotron X-ray tomography at high pressure and temperature allowing complete high-resolution tomograms to be acquired in about 10 s. This gives direct visualization to rapidly evolving or unstable systems, such as flowing liquids or reacting components, and avoids assumptions in the interpretation of quenched samples. Using algebraic reconstruction techniques allows the missing angle artefacts that result from the columns of the press to be minimized.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França