P1 cortical auditory evoked potential in children with unilateral or bilateral cochlear implants; implication for the timing of second cochlear implantation.
Jeong, Sung Wook; Chung, Seung Hyun; Kim, Lee-Suk.
Afiliação
  • Jeong SW; Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Dong-A University, 3-1 Dongdaeshin-dong, Seo-gu, Busan, 602-715, South Korea.
  • Chung SH; Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Dong-A University, 3-1 Dongdaeshin-dong, Seo-gu, Busan, 602-715, South Korea.
  • Kim LS; Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Dong-A University, 3-1 Dongdaeshin-dong, Seo-gu, Busan, 602-715, South Korea. klsolkor@chol.com.
Eur Arch Otorhinolaryngol ; 275(7): 1759-1765, 2018 Jul.
Article em En | MEDLINE | ID: mdl-29855691
ABSTRACT

OBJECTIVE:

To examine maturation of the central auditory pathway, using P1 cortical auditory evoked potential (CAEP), in children who had received unilateral or bilateral cochlear implantation (CI). STUDY

DESIGN:

Prospective study.

SETTING:

Tertiary referral hospital.

METHODS:

Twenty children who had received CI due to congenital, or prelingual, deafness participated in the study. Participants had received the 1st implant at a mean age of 3.4 ± 0.7 years; 16 had also received a 2nd CI for the contralateral ear, at a mean age of 11.1 ± 2.1 years. P1 CAEP was recorded while using the 1st implant and, for those who received contralateral CI, within 2 weeks of switching on the 2nd implant. Relations between P1 latency and duration with the 1st implant, and between age at 1st CI and P1 latency, were investigated. Relations between P1 latency with the 1st and 2nd implants, and between the interstage interval and difference between P1 latencies with the 1st and 2nd implants, were also examined.

RESULTS:

P1 CAEP with the 1st implant was present in 16 of the 20 children. Mean P1 latency was shorter in the early CI group compared with the late CI group, but this difference was not statistically significant (p = 0.154). There was a significant negative correlation between the duration with the 1st implant and P1 latency (r = - 0.783, p < 0.001). Among the 16 children with sequential bilateral CI, P1 CAEP with the 2nd implant was present in 10. There was a significant negative correlation between the duration with the 1st implant before receiving the 2nd implant and P1 latency with the 2nd implant (r = - 0.710, p = 0.021); there was also a significant positive correlation between P1 latency with the 1st and 2nd implants (r = 0.722, p = 0.018). There was not a significant correlation between interstage interval and the difference between the two P1 latencies (r = - 0.430, p = 0.248).

CONCLUSION:

Longer cochlear implant use is associated with shorter P1 latency. Unilateral hearing with the 1st implant may positively affect P1 latency with the 2nd CI ear. These findings imply that increased auditory experience may influence central auditory pathway maturation and that the degree of central auditory pathway maturation before the 2nd CI, rather than the timing when the surgery is received, may influence 2nd CI outcome in children with sequential bilateral cochlear implants.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Cocleares / Implante Coclear / Surdez / Potenciais Evocados Auditivos Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Cocleares / Implante Coclear / Surdez / Potenciais Evocados Auditivos Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Coréia do Sul