Your browser doesn't support javascript.
loading
Development of a hard X-ray split-and-delay line and performance simulations for two-color pump-probe experiments at the European XFEL.
Lu, W; Friedrich, B; Noll, T; Zhou, K; Hallmann, J; Ansaldi, G; Roth, T; Serkez, S; Geloni, G; Madsen, A; Eisebitt, S.
Afiliação
  • Lu W; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Friedrich B; Max Born Institute, Max-Born-Strasse 2A, 12489 Berlin, Germany.
  • Noll T; Max Born Institute, Max-Born-Strasse 2A, 12489 Berlin, Germany.
  • Zhou K; Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 201800 Shanghai, China.
  • Hallmann J; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Ansaldi G; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Roth T; ESRF-The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Serkez S; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Geloni G; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Madsen A; European X-Ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Eisebitt S; Max Born Institute, Max-Born-Strasse 2A, 12489 Berlin, Germany.
Rev Sci Instrum ; 89(6): 063121, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29960553
ABSTRACT
A hard X-ray Split-and-Delay Line (SDL) under construction for the Materials Imaging and Dynamics station at the European X-Ray Free-Electron Laser (XFEL) is presented. This device aims at providing pairs of X-ray pulses with a variable time delay ranging from -10 ps to 800 ps in a photon energy range from 5 to 10 keV for photon correlation and X-ray pump-probe experiments. A custom designed mechanical motion system including active feedback control ensures that the high demands for stability and accuracy can be met and the design goals achieved. Using special radiation configurations of the European XFEL's SASE-2 undulator (SASE Self-Amplified Spontaneous Emission), two-color hard x-ray pump-probe schemes with varying photon energy separations have been proposed. Simulations indicate that more than 109 photons on the sample per pulse-pair and up to about 10% photon energy separation can be achieved in the hard X-ray region using the SDL.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha