Field evaluation of a real time loop-mediated isothermal amplification assay (RealAmp) for malaria diagnosis in Cruzeiro do Sul, Acre, Brazil.
Viana, Giselle Maria Rachid; Silva-Flannery, Luciana; Lima Barbosa, Danielle Regina; Lucchi, Naomi; do Valle, Suiane Costa Negreiros; Farias, Samela; Barbalho, Nayara; Marchesini, Paola; Rossi, Juliana Chedid Nogaredi; Udhayakumar, Venkatachalam; Póvoa, Marinete Marins; de Oliveira, Alexandre Macedo.
Afiliação
  • Viana GMR; Instituto Evandro Chagas-IEC/SVS/MS, S/N° Bairro: Levilândia, Ananindeua, Pará, Brasil.
  • Silva-Flannery L; Malaria Branch, Division of Parasitic Diseases and Malaria, Centers for Global Health, Centers for Disease Control and Prevention, Atlanta, GA, United States of America.
  • Lima Barbosa DR; Instituto Evandro Chagas-IEC/SVS/MS, S/N° Bairro: Levilândia, Ananindeua, Pará, Brasil.
  • Lucchi N; Malaria Branch, Division of Parasitic Diseases and Malaria, Centers for Global Health, Centers for Disease Control and Prevention, Atlanta, GA, United States of America.
  • do Valle SCN; Secretaria Estadual de Saude do Acre-Hemonúcleo Cruzeiro do Sul. Manuel Terças, Cruzeiro do Sul-Acre-Brasil.
  • Farias S; Secretaria Estadual de Saude do Acre-Hemonúcleo Cruzeiro do Sul. Manuel Terças, Cruzeiro do Sul-Acre-Brasil.
  • Barbalho N; Secretaria Estadual de Saude do Acre-Hemonúcleo Cruzeiro do Sul. Manuel Terças, Cruzeiro do Sul-Acre-Brasil.
  • Marchesini P; Coordenação Geral do Programa Nacional de Controle da Malária e Doenças Transmitidas pelo Aedes- CGPNCM Setor Comercial Sul, Edifício Principal, Brasília/DF, Brasil.
  • Rossi JCN; Coordenação Geral do Programa Nacional de Controle da Malária e Doenças Transmitidas pelo Aedes- CGPNCM Setor Comercial Sul, Edifício Principal, Brasília/DF, Brasil.
  • Udhayakumar V; Malaria Branch, Division of Parasitic Diseases and Malaria, Centers for Global Health, Centers for Disease Control and Prevention, Atlanta, GA, United States of America.
  • Póvoa MM; Instituto Evandro Chagas-IEC/SVS/MS, S/N° Bairro: Levilândia, Ananindeua, Pará, Brasil.
  • de Oliveira AM; Malaria Branch, Division of Parasitic Diseases and Malaria, Centers for Global Health, Centers for Disease Control and Prevention, Atlanta, GA, United States of America.
PLoS One ; 13(7): e0200492, 2018.
Article em En | MEDLINE | ID: mdl-29995953
ABSTRACT
Conventional molecular methods, such as nested polymerase chain reaction (PCR), are very sensitive for detection of malaria parasites, but require advanced laboratory equipment and trained personnel. Real-time loop-mediated isothermal amplification (RealAmp), a loop-mediated isothermal amplification-based molecular tool (LAMP), facilitates rapid target amplification at a single temperature setting, reducing the need for sophisticated equipment. We evaluated the performance of a field-adapted RealAmp assay for malaria diagnosis in Cruzeiro do Sul, Acre State, Brazil, a remote area in Brazil with limited laboratory capabilities. We enrolled 1,000 patients with fever (axillary temperature ≥ 37.5 C) or history of fever in last 24 h presenting for malaria diagnosis from February through June 2015. DNA was extracted from dried blood spots using a boil and spin method (heat treatment) at the sample processing site, and also using commercial kits at a Brazilian national reference laboratory. RealAmp was performed for Plasmodium genus, P. falciparum, and P. vivax identification. In addition, Giemsa-stained blood smears were prepared and examined by two independent well-trained study microscopists. A combination of Real-time PCR and nested PCR was used as reference test. The sensitivity and specificity of RealAmp in the field site laboratory were 94.1% (95% confidence interval [CI] 90.1-96.8) and 83.9% (95% CI 81.1-86.4), respectively. The sensitivity and specificity of local microscopy were 87.7% (95% CI 82.6-91.7) and 98.9% (95% CI 97.8-99.4), respectively, while study microscopy showed sensitivity of 96.4% (95% CI 93.0-98.4) and specificity of 98.2% (95% CI 97.0-99.0). None of the three tests detected 20 P. falciparum and P. vivax mixed infections identified by the reference test. Our findings highlight that it is possible to implement simple molecular tests in facilities with limited resources such as Cruzeiro do Sul in Brazil. RealAmp sensitivity was similar to that of microscopy performed by skilled professionals; both RealAmp and study microscopy performed poorly in detection of mixed infection. Attempts to develop and evaluate simpler molecular tools should continue, especially for the detection of malaria infection in remote areas.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plasmodium falciparum / Plasmodium vivax / Malária Vivax / Malária Falciparum / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Female / Humans / Male País/Região como assunto: America do sul / Brasil Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plasmodium falciparum / Plasmodium vivax / Malária Vivax / Malária Falciparum / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Female / Humans / Male País/Região como assunto: America do sul / Brasil Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil