Your browser doesn't support javascript.
loading
Catheter Induced Mechanical Suppression of Outflow-tract Arrhythmias: Incidence, Characteristics, and Significance.
Michowitz, Yoav; Ben-Shoshan, Jeremy; Tovia-Brodie, Oholi; Glick, Aharon; Belhassen, Bernard.
Afiliação
  • Michowitz Y; Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, affiliated with Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Ben-Shoshan J; Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, affiliated with Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Tovia-Brodie O; Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, affiliated with Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Glick A; Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, affiliated with Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Belhassen B; Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, affiliated with Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Isr Med Assoc J ; 20(8): 467-471, 2018 Aug.
Article em En | MEDLINE | ID: mdl-30084569
ABSTRACT

BACKGROUND:

The incidence, characteristics, and clinical significance of catheter-induced mechanical suppression (trauma) of ventricular arrhythmias originating in the outflow tract (OT) area have not been thoroughly evaluated.

OBJECTIVES:

To determine these variables among our patient cohort.

METHODS:

All consecutive patients with right ventricular OT (RVOT) and left ventricular OT (LVOT) arrhythmias ablated at two medical centers from 1998 to 2014 were included. Patients were observed for catheter-induced trauma during ablation procedures. Procedural characteristics, as well as response to catheter-induced trauma and long term follow-up, were recorded.

RESULTS:

During 288 ablations of OT arrhythmias in 273 patients (RVOT n=238, LVOT n=50), we identified 8 RVOT cases (3.3%) and 1 LVOT (2%) case with catheter-induced trauma. Four cases of trauma were managed by immediate radiofrequency ablation (RFA), three were ablated after arrhythmia recurrence within a few minutes, and two were ablated after > 30 minutes without arrhythmia recurrence. Patients with catheter-induced trauma had higher rates of repeat ablations compared to patients without 3/9 (33%) vs. 12/264 (0.45%), P = 0.009. The three patients with arrhythmia recurrence were managed differently during the first ablation procedure (immediate RFA, RFA following early recurrence, and delayed RFA). During the repeat procedure of these three patients, no catheter trauma occurred in two, and in one no arrhythmia was observed.

CONCLUSIONS:

Significant catheter-induced trauma occurred in 3.1% of OT arrhythmias ablations, both at the RVOT and LVOT. Arrhythmia suppression may last > 30 minutes and may interfere with procedural success. The optimal mode of management following trauma is undetermined.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ablação por Cateter / Ventrículos do Coração / Complicações Intraoperatórias Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Isr Med Assoc J Assunto da revista: MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ablação por Cateter / Ventrículos do Coração / Complicações Intraoperatórias Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Isr Med Assoc J Assunto da revista: MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel