Dynamic 11C-Choline PET / CT for the primary diagnosis of prostate cancer.
Golan, Shay; Nidam, Meital; Bernstine, Hanna; Baniel, Jack; Groshar, David.
Afiliação
  • Golan S; Institute of Urology, Rabin Medical Center - Beilinson Hospital, Petach Tikva, Sackler Faculty of Medicine, Israel.
  • Nidam M; Department of Nuclear Medicine, Rabin Medical Center - Beilinson Hospital, Petach Tikva, Sackler Faculty of Medicine, Israel.
  • Bernstine H; Department of Nuclear Medicine, Rabin Medical Center - Beilinson Hospital, Petach Tikva, Sackler Faculty of Medicine, Israel.
  • Baniel J; Institute of Urology, Rabin Medical Center - Beilinson Hospital, Petach Tikva, Sackler Faculty of Medicine, Israel.
  • Groshar D; Department of Nuclear Medicine, Rabin Medical Center - Beilinson Hospital, Petach Tikva, Sackler Faculty of Medicine, Israel.
Int Braz J Urol ; 44(5): 900-905, 2018.
Article em En | MEDLINE | ID: mdl-30088719
ABSTRACT

OBJECTIVES:

To test the ability of dynamic 11C-PET / CT to discriminate cancerous tissue from background tissue in patients with localized prostate cancer. MATERIALS AND

METHODS:

Twenty-four consecutive patients with prostate cancer were prospectively evaluated with dynamic 11C-choline PET / CT prior to radical prostatectomy. The PET / CT scan was divided into 18 sequences of 5 seconds each, followed by 9 sequences of 60 seconds each. Whole-mount sections of harvested prostates served as reference standards. Volumes of interest were positioned on the dynamic PET / CT images and the following quantitative variables were calculated perfusion coefficient (K1), washout constant (K2), area under the curve (AUC) at 175 and 630 seconds, and average and maximum standardized uptake values (SUVavg, and SUVmax). Wilcoxon signed-ranks test was used to compare benign and cancerous areas of the prostate.

RESULTS:

Areas of cancerous tissue were characterized by higher SUVavg and SUVmax than areas of benign tissue (3.67 ± 2.7 vs. 2.08 ± 1.3 and 5.91 ± 4.4 vs. 3.71 ± 3.7, respectively, P < 0.001), in addition to a higher K1 (0.95 ± 0.58 vs. 0.43 ± 0.24, P < 0.001) and greater cumulative tracer uptake, represented by the AUC at 175 and 630 seconds (P <0.001). No associations were found between dynamic parameters and preoperative prostate specific antigen level or Gleason score.

CONCLUSIONS:

In this pilot study, 11C-choline PET / CT demonstrated increased tracer uptake with higher values of static and dynamic parameters in areas of prostate cancer compared to areas of benign tissue. Larger studies are warranted to validate these results and examine the potential applicability of 11C-choline dynamic PET / CT for the diagnosis of prostate cancer.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioisótopos de Carbono / Colina / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Int Braz J Urol Assunto da revista: UROLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioisótopos de Carbono / Colina / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Int Braz J Urol Assunto da revista: UROLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel