Your browser doesn't support javascript.
loading
Removal of subcutaneous defibrillator shocking coils: Lessons to learn for future extraction of subcutaneous defibrillator systems.
Nakhla, Shady; Hussein, Ayman A; Brunner, Michael P; Wazni, Oussama; Wilkoff, Bruce L; Tarakji, Khaldoun G.
Afiliação
  • Nakhla S; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Hussein AA; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Brunner MP; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Wazni O; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Wilkoff BL; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Tarakji KG; Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.
Pacing Clin Electrophysiol ; 41(10): 1341-1344, 2018 10.
Article em En | MEDLINE | ID: mdl-30132950
BACKGROUND: Subcutaneous shocking coils (SQC) have been used to lower defibrillation thresholds in certain patient populations. There are limited data regarding the extraction complexity of these leads. The goal of this study is to describe our SQC extraction experience and identify challenges that may be of importance with the increase in utilization and extraction of fully subcutaneous defibrillator systems. METHODS: We studied consecutive patients who underwent lead removal at our institution during which a Medtronic 6996SQ (Medtronic plc, Minneapolis, MN, USA) was removed RESULTS: Twenty-one patients (54.5 ± 14 years, 85.7% male) underwent procedures where at least one lead removed was a SQC. Mean ejection fraction was 27.7% and 11 patients had prior ventricular arrhythmia. Median SQC age was 177 days and the age of the oldest SQC removed was 3,041 days. Infection was the indication for removal in 14 patients. One removal was performed surgically and 20 were completed percutaneously. Three procedures required additional incisions beyond the device pocket and tie-down sleeve to complete the SQC lead removal due to dense adhesions. One removal procedure required the use of a laser sheath to relieve fibrosis. Complications in this group did not appear related to SQC removal. CONCLUSIONS: Drawing from our SQC removal experience, there may be a need for additional incisions and extra tools to complete removal of older subcutaneous implantable cardioverter defibrillator leads.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Remoção de Dispositivo / Eletrodos Implantados Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Remoção de Dispositivo / Eletrodos Implantados Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos