Your browser doesn't support javascript.
loading
Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging.
Leva, Lucia; Matheoud, Roberta; Sacchetti, Gianmauro; Carriero, Alessandro; Brambilla, Marco.
Afiliação
  • Leva L; Department of Nuclear Medicine, University Hospital 'Maggiore della Carità', Novara, Italy.
  • Matheoud R; Department of Medical Physics, University Hospital 'Maggiore della Carità', Novara, Italy.
  • Sacchetti G; Department of Nuclear Medicine, University Hospital 'Maggiore della Carità', Novara, Italy.
  • Carriero A; Department of Radiology, University Hospital 'Maggiore della Carità', Novara, Italy.
  • Brambilla M; Department of Medical Physics, University Hospital 'Maggiore della Carità', Novara, Italy. marco.brambilla@maggioreosp.novara.it.
J Nucl Cardiol ; 27(5): 1714-1724, 2020 10.
Article em En | MEDLINE | ID: mdl-30298371
BACKGROUND: The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. METHODS: Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. RESULTS: In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. CONCLUSIONS: The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália