Your browser doesn't support javascript.
loading
The association of variables of fibular reconstructed mandible and bite force in oral cancer patients with dental implant rehabilitation.
Huang, Yi-Fang; Chang, Chung-Ta; Muo, Chih-Hsin; Hong, Hsiang-Hsi; Shen, Yu-Fu; Lin, Chia-Chang; Liu, Shih-Ping.
Afiliação
  • Huang YF; Department of General Dentistry, Chang Gung Memorial Hospital, Linkou, 33305, Taiwan; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, 11031, Taiwan. Electronic address: yifang0324@gmail.com.
  • Chang CT; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, 11031, Taiwan; Department of Emergency Medicine, Far Eastern Memorial Hospital, New Taipei, 22056, Taiwan.
  • Muo CH; Management Office for Health Data, China Medical University Hospital, Taichung, 40402, Taiwan.
  • Hong HH; Department of Periodontology, Chang Gung Memorial Hospital, Linkou, 33305, Taiwan.
  • Shen YF; Department of General Dentistry, Chang Gung Memorial Hospital, Linkou, 33305, Taiwan.
  • Lin CC; Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan, 33302, Taiwan; Department of Psychiatry, Chang Gung Memorial Hospital, Linkou, 33305, Taiwan.
  • Liu SP; Graduate Institute of Basic Medical Science, China Medical University, Taichung, 40402, Taiwan; Center for Neuropsychiatry, China Medical University Hospital, Taichung, 40402, Taiwan; Department of Social Work, Asia University, Taichung, 41354, Taiwan. Electronic address: spliu@mail.cmuh.org.tw.
J Craniomaxillofac Surg ; 46(11): 1979-1983, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30301649
PURPOSE: The aim of this study was to investigate how the physical variables of fibular reconstructed mandibles with dental implants affects the relative bite force in oral cancer patients. MATERIALS AND METHODS: Over 7 years of follow-up, 13 oral cancer patients were enrolled who included 51 successful implants in the fibular flap. The tactile sensor analyzer evaluated the bite force. The crown-implant ratio, fibular, and rehabilitated dental length were measured using radiographic images. Linear regression was used to analyze the bite force related to the variables of the implants in the fibular reconstructed mandible. RESULTS: Even when the results showed no statistical significance (P > 0.05), increasing the crown-implant ratio, length of the fibular flap, and implant prosthetic reconstructed dentition had a tendency to decrease the bite force (estimate from -0.08% to -4.27%); there was a positive trend of occlusal force and the length of rehabilitative dentition compared with the dental antagonist (estimate = 6.95). CONCLUSION: In this study, the crown-implant ratio, implant dentition, and fibular flap length revealed no significant impact on the bite force or implant success in oral cancer patients; however, a trend to weaken the bite force was suggested once the numerical values of these variables increased.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força de Mordida / Neoplasias Bucais / Implantes Dentários / Implantação Dentária Endóssea / Retalhos de Tecido Biológico / Fíbula / Reconstrução Mandibular Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Craniomaxillofac Surg Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força de Mordida / Neoplasias Bucais / Implantes Dentários / Implantação Dentária Endóssea / Retalhos de Tecido Biológico / Fíbula / Reconstrução Mandibular Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Craniomaxillofac Surg Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article