Your browser doesn't support javascript.
loading
A Fluidic Biosensor Based on a Phase-Sensitive Low-Coherence Spectral-Domain Interferometer.
Guo, Cuixia; Yang, Xiaojie; Shen, Zhiyuan; Wu, Jian-Ping; Zhong, Suyi; He, Yonghong; Guan, Tian; Chen, Fangyi.
Afiliação
  • Guo C; Department of Physics, Tsinghua University, Beijing 100084, China. guo_c_x@163.com.
  • Yang X; Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China. guo_c_x@163.com.
  • Shen Z; Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China. yangxj3@sustc.edu.cn.
  • Wu JP; Orbbec Co., Ltd., 12/F, No. 63 Xuefu Road, Nanshan District, Shenzhen 518055, China. shenzhiyuan@orbbec.com.
  • Zhong S; Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China. wujp@sustc.edu.cn.
  • He Y; Academy of Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen 518055, China. wujp@sustc.edu.cn.
  • Guan T; Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China. sueyi166@163.com.
  • Chen F; School of Medicine, Tsinghua University, Beijing 100084, China. sueyi166@163.com.
Sensors (Basel) ; 18(11)2018 Nov 03.
Article em En | MEDLINE | ID: mdl-30400305
A phase-sensitive fluidic biosensor based on a spectral-domain low-coherence interferometer is presented in this paper. With a fiber optic probe employing the common-path interferometric configuration, subnanometric changes in thickness of the molecular layers can be detected through phase analysis of the acquired interference signal from the sensor surface. Advantages of this biosensor include its picometer-scale thickness sensitivity, 13.9-ms time response, and tolerance to the fluctuation in concentration of the target solution. The capabilities of this biosensor in monitoring specific molecular binding and recognizing specific molecular was successfully demonstrated by using the reactions between the molecules of protein A and IgG. The calculated minimum detectable concentration of IgG is 0.11 µg/mL.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China