Your browser doesn't support javascript.
loading
One-millimeter isotropic breast diffusion-weighted imaging: Evaluation of a superresolution strategy in terms of signal-to-noise ratio, sharpness and apparent diffusion coefficient.
Delbany, Maya; Bustin, Aurélien; Poujol, Julie; Thomassin-Naggara, Isabelle; Felblinger, Jacques; Vuissoz, Pierre-André; Odille, Freddy.
Afiliação
  • Delbany M; IADI, INSERM U1254 and Université de Lorraine, Nancy, France.
  • Bustin A; School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
  • Poujol J; IADI, INSERM U1254 and Université de Lorraine, Nancy, France.
  • Thomassin-Naggara I; Laboratoire de Recherche en Imagerie INSERM, Université Paris Descartes, Sorbonne Paris Cité, PARCC UMR 970, Faculté de médecine.
  • Felblinger J; IADI, INSERM U1254 and Université de Lorraine, Nancy, France.
  • Vuissoz PA; CIC-IT 1433, INSERM, CHRU de Nancy and Université de Lorraine, Nancy, France.
  • Odille F; IADI, INSERM U1254 and Université de Lorraine, Nancy, France.
Magn Reson Med ; 81(4): 2588-2599, 2019 04.
Article em En | MEDLINE | ID: mdl-30536764
ABSTRACT

PURPOSE:

To quantitatively evaluate a superresolution technique for 3D, one-millimeter isotropic diffusion-weighted imaging (DWI) of the whole breasts.

METHODS:

Isotropic 3D DWI datasets are obtained using a combination of (i) a readout-segmented diffusion-weighted-echo-planar imaging (DW-EPI) sequence (rs-EPI), providing high in-plane resolution, and (ii) a superresolution (SR) strategy, which consists of acquiring 3 datasets with thick slices (3 mm) and 1-mm shifts in the slice direction, and combining them into a 1 × 1 × 1-mm3 dataset using a dedicated reconstruction. Two SR reconstruction schemes were investigated, based on different regularization schemes conventional Tikhonov or Beltrami (an edge-preserving constraint). The proposed SR strategy was compared to native 1 × 1 × 1-mm3 acquisitions (i.e. with 1-mm slice thickness) in 8 healthy subjects, in terms of signal-to-noise ratio (SNR) efficiency, using a theoretical framework, Monte Carlo simulations and region-of-interest (ROI) measurements, and image sharpness metrics. Apparent diffusion coefficient (ADC) values in normal breast tissue were also compared.

RESULTS:

The SR images resulted in an SNR gain above 3 compared to native 1 × 1 × 1-mm3 using the same acquisition duration (acquisition gain 3 and reconstruction gain >1). Beltrami-SR provided the best results in terms of SNR and image sharpness. The ADC values in normal breast measured from Beltrami-SR were preserved compared to low-resolution images (1.91 versus 1.97 ×10-3 mm2 /s, P = .1).

CONCLUSION:

A combination of rs-EPI and SR allows 3D, 1-mm isotropic breast DWI data to be obtained with better SNR than a native 1-mm isotropic acquisition. The proposed DWI protocol might be of interest for breast cancer monitoring/screening without injection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Health_economic_evaluation Limite: Adult / Female / Humans / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Health_economic_evaluation Limite: Adult / Female / Humans / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França