Your browser doesn't support javascript.
loading
Assembled Step Emulsification Device for Multiplex Droplet Digital Polymerase Chain Reaction.
Nie, Mengyue; Zheng, Meng; Li, Caiming; Shen, Feng; Liu, Manhua; Luo, Haibei; Song, Xiaohui; Lan, Ying; Pan, Jian-Zhang; Du, Wenbin.
Afiliação
  • Nie M; State Key Laboratory of Microbial Resources, Institute of Microbiology , Chinese Academy of Sciences , 100101 , Beijing , China.
  • Zheng M; College of Life Sciences , University of the Chinese Academy of Sciences , Beijing , 10049 , China.
  • Li C; State Key Laboratory of Microbial Resources, Institute of Microbiology , Chinese Academy of Sciences , 100101 , Beijing , China.
  • Shen F; Savaid Medical School , University of the Chinese Academy of Sciences , Beijing , 10049 , China.
  • Liu M; State Key Laboratory of Microbial Resources, Institute of Microbiology , Chinese Academy of Sciences , 100101 , Beijing , China.
  • Luo H; College of Life Sciences , University of the Chinese Academy of Sciences , Beijing , 10049 , China.
  • Song X; School of Biomedical Engineering , Shanghai Jiao Tong University , Shanghai 200240 , China.
  • Lan Y; Department of Instrument Science and Engineering, The School of Electronic Information and Electrical Engineering , Shanghai Jiao Tong University , Shanghai 200240 , China.
  • Pan JZ; Pilot Gene Technologies , Hangzhou , 311203 , China.
  • Du W; Pilot Gene Technologies , Hangzhou , 311203 , China.
Anal Chem ; 91(3): 1779-1784, 2019 02 05.
Article em En | MEDLINE | ID: mdl-30608139
ABSTRACT
Digital PCR is a powerful method for absolute nucleic acid quantification with unprecedented accuracy and precision. To promote the wider use and application of digital PCR, several major challenges still exist, including reduction of cost, integration of the instrumental platform, and simplification of operations. This paper describes a reusable microfluidic device that generates nanoliter droplet arrays based on step emulsification for the on-chip multiplex digital PCR of eight samples simultaneously. The device contains two glass plates that can be quickly assembled with prefilled mineral oil. Droplets are simply generated through the arrays of step emulsification nozzles driven by a single pressure controller and are self-assembled into monolayer droplet arrays in U-shaped chambers. The use of mineral oil eliminates bubble generation; thus, no overpressure is required during thermocycling. Moreover, the device can be reused many times after disassembly and a brief cleaning procedure, which significantly reduces the cost of the device per dPCR assays. The device was able to detect template DNA at concentrations as low as 10 copies/µL with a dynamic range of approximately 4 logs. We applied this device in the quantitative assessment of HER2 copy number variation, which is important for targeted therapy and prognosis of breast cancer. The performance was validated by 16 clinical samples, obtaining similar results to commercial digital PCR. We envision that this low-cost, reusable, and user-friendly device can be broadly used in various applications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA de Neoplasias / Dispositivos Lab-On-A-Chip / Reação em Cadeia da Polimerase Multiplex Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA de Neoplasias / Dispositivos Lab-On-A-Chip / Reação em Cadeia da Polimerase Multiplex Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China