Your browser doesn't support javascript.
loading
Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks.
van der Straaten, Rob; Bruijnes, Amber K B D; Vanwanseele, Benedicte; Jonkers, Ilse; De Baets, Liesbet; Timmermans, Annick.
Afiliação
  • van der Straaten R; REVAL Rehabilitation Research Center, Hasselt University, Agoralaan Building A, 3560 Diepenbeek, Belgium. rob.vanderstraaten@uhasselt.be.
  • Bruijnes AKBD; Department of Orthopaedics, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600 Genk, Belgium. amber.bruijnes@zol.be.
  • Vanwanseele B; Department of Movement Sciences, Human Movement Biomechanics, KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium. benedicte.vanwanseele@kuleuven.be.
  • Jonkers I; Department of Movement Sciences, Human Movement Biomechanics, KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium. ilse.jonkers@kuleuven.be.
  • De Baets L; REVAL Rehabilitation Research Center, Hasselt University, Agoralaan Building A, 3560 Diepenbeek, Belgium. liesbet.debaets@uhasselt.be.
  • Timmermans A; REVAL Rehabilitation Research Center, Hasselt University, Agoralaan Building A, 3560 Diepenbeek, Belgium. annick.timmermans@uhasselt.be.
Sensors (Basel) ; 19(1)2019 Jan 03.
Article em En | MEDLINE | ID: mdl-30609808
This study evaluates the reliability and agreement of the 3D range of motion (ROM) of trunk and lower limb joints, measured by inertial measurement units (MVN BIOMECH Awinda, Xsens Technologies), during a single leg squat (SLS) and sit to stand (STS) task. Furthermore, distinction was made between movement phases, to discuss the reliability and agreement for different phases of both movement tasks. Twenty healthy participants were measured on two testing days. On day one, measurements were conducted by two operators to determine the within-session and between-operator reliability and agreement. On day two, measurements were conducted by the same operator, to determine the between-session reliability and agreement. The SLS task had lower within-session reliability and agreement compared with between-session and between-operator reliability and agreement. The reliability and agreement of the hip, knee, and ankle ROM in the sagittal plane were good for both phases of the SLS task. For both phases of STS task, within-session reliability and agreement were good, and between-session and between-operator reliability and agreement were lower in all planes. As both tasks are physically demanding, differences may be explained by inconsistent movement strategies. These results show that inertial sensor systems show promise for use in further research to investigate (mal)adaptive movement strategies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Extremidade Inferior / Tronco / Acelerometria / Movimento Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Extremidade Inferior / Tronco / Acelerometria / Movimento Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Bélgica