In vitro retention efficiency of temporary type zinc oxide cement for orthodontic forced eruption.
Nieto-Aguilar, Renato; Serrato-Ochoa, Deyanira; Medina-Navarro, Rafael; Aguilera-Méndez, Asdrúbal; Morales-Soto, Karina Denisse; Loyola-Rodriguez, Juan Pablo; Campos, Antonio; Alaminos, Miguel.
Afiliação
  • Nieto-Aguilar R; Universidad Michoacana de San Nicolás de Hidalgo, Faculty of Odontology, Postgraduate Studies Division, Morelia, Michoacán, Mexico. Electronic address: rnieto@umich.mx.
  • Serrato-Ochoa D; Universidad Michoacana de San Nicolás de Hidalgo, Faculty of Odontology, Postgraduate Studies Division, Morelia, Michoacán, Mexico.
  • Medina-Navarro R; Biomedical Research Centre in Michoacán (CIBIMI-IMSS), Morelia, Michoacán, Mexico.
  • Aguilera-Méndez A; Chemical and Biological Investigation Institute, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán, Mexico.
  • Morales-Soto KD; Universidad Michoacana de San Nicolás de Hidalgo, Faculty of Odontology, Postgraduate Studies Division, Morelia, Michoacán, Mexico.
  • Loyola-Rodriguez JP; Universidad Autónoma de Baja California, Faculty of Dentistry, Tijuana, Baja California, Mexico.
  • Campos A; University of Granada, Faculty of Medicine and Faculty of Odontology, Granada, Spain.
  • Alaminos M; University of Granada, Faculty of Medicine and Faculty of Odontology, Granada, Spain.
Int Orthod ; 17(1): 96-102, 2019 03.
Article em En | MEDLINE | ID: mdl-30772354
ABSTRACT

OBJECTIVE:

To assess the retention efficiency of three types of temporary zinc oxide cement trademarks on forced eruption using intracranal wire device.

METHODS:

An in vitro evaluation included intracanal wire device displacement and detachment at 50g load force for 120 days and then the retention resistance at maximum load force.

RESULTS:

All groups of temporary zinc oxide cements were efficient to support 50g load forces after 120 days. None statistical differences were found between groups. Zinc oxide cements supported a maximum retention load force, which exceeded in more than 84 times the lowest value obtained in controls (420g).

CONCLUSION:

Zinc oxide cements are efficient to retain intracanal wire devices on forced eruption processes in vitro and allows removal of both when necessary (wire device and cement, respectively).