Your browser doesn't support javascript.
loading
Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread.
Glazebrook, Katrina N; Doerge, Stefan; Leng, Shuai; Drees, Tammy A; Hunt, Katie N; Zingula, Shannon N; Pruthi, Sandhya; Geske, Jennifer R; Carter, Rickey E; McCollough, Cynthia H; Fletcher, Joel G.
Afiliação
  • Glazebrook KN; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Doerge S; 2 Aurora West Allis Medical Center, West Allis, WI.
  • Leng S; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Drees TA; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Hunt KN; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Zingula SN; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Pruthi S; 3 Department of General Internal Medicine, Mayo Clinic, Rochester, MN.
  • Geske JR; 4 Department of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN.
  • Carter RE; 5 Department of Health Sciences Research, Mayo Clinic, Jacksonville, FL.
  • McCollough CH; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
  • Fletcher JG; 1 Department of Radiology, 200 First St SW, Mayo Clinic, Rochester, MN 55905.
AJR Am J Roentgenol ; 212(4): 933-942, 2019 04.
Article em En | MEDLINE | ID: mdl-30779664
OBJECTIVE: The purpose of this study is to compare the performance of dual-energy CT (DECT) with that of breast MRI for detection of silicone gel breast implant rupture and nodal spread of silicone. SUBJECTS AND METHODS: This prospective study enrolled consecutive patients with current or prior silicone gel implants and clinical suspicion of implant rupture or extra-capsular silicone. All patients underwent MRI followed by unenhanced DECT. A breast radiologist not participating in image evaluation established reference standards for implant rupture (intra- or extracapsular) and regional nodal silicone spread (to axillary nodes and internal mammary [IM] and mediastinal nodes) using MRI, surgical findings, and medical records. After undergoing reader training, two radiologists who were blinded to all medical records interpreted randomized images in two sessions, indicating confidence in diagnosis using a 100-point visual scale. RESULTS: A total of 46 patients who had a subpectoral silicone gel implant (n = 31), a subglandular silicone gel implant (n = 14), or a silicone gel implant that was removed (n = 1) underwent MRI and DECT (mean [± SD] volume CT dose index, 8.2 ± 2.0 mGy). Nineteen patients had implant rupture, and 13 of these patients had silicone within the IM or axillary nodes. Pooled data showed no significant difference between MRI and DECT interpretation of intra- or extracapsular rupture of implants (AUC value for intracapsular rupture, 0.958 [for MRI] vs 0.989 [for DECT]; p = 0.28; AUC value for extracapsular rupture, 0.864 [for MRI] vs 0.878 [for DECT]; p = 0.78). No difference was noted in the AUC value for silicone spread to regional lymph nodes: 0.823-0.866 [for MRI] vs 0.892-0.906 [for DECT]; p = 0.34-0.54). CONCLUSION: DECT performs similar to MRI for the detection of silicone gel implant rupture and the presence of silicone in regional lymph nodes, and it may be an alternative for patients who are unable or unwilling to undergo MRI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Implantes de Mama / Extravasamento de Materiais Terapêuticos e Diagnósticos Tipo de estudo: Clinical_trials / Guideline / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Implantes de Mama / Extravasamento de Materiais Terapêuticos e Diagnósticos Tipo de estudo: Clinical_trials / Guideline / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2019 Tipo de documento: Article