Your browser doesn't support javascript.
loading
Evaluating the potential of near infrared hyperspectral imaging associated with multivariate data analysis for examining crossing ink lines.
Rodrigues E Brito, Lívia; Braz, André; Saldanha Honorato, Ricardo; Pimentel, Maria Fernanda; Pasquini, Celio.
Afiliação
  • Rodrigues E Brito L; Institute of Criminalistics of Pernambuco, Recife, Brazil; Department of Fundamental Chemistry, Federal University of Pernambuco, Recife, Brazil.
  • Braz A; Department of Fundamental Chemistry, Federal University of Pernambuco, Recife, Brazil. Electronic address: andrefrmbraz@gmail.com.
  • Saldanha Honorato R; Federal Police, Pernambuco, Brazil.
  • Pimentel MF; Department of Chemical Engineering, Federal University of Pernambuco, Recife, Brazil.
  • Pasquini C; Chemistry Institute, University of Campinas, Campinas, Brazil.
Forensic Sci Int ; 298: 169-176, 2019 May.
Article em En | MEDLINE | ID: mdl-30909104
ABSTRACT
The determination of the chronological sequence of crossing ink lines is a recurrent issue in the forensic examination of questioned documents. This manuscript intends to evaluate the potential of hyperspectral imaging in the near infrared range (HSI-NIR) combined with multivariate data analysis for rapid, objective and nondestructive analysis of crossing ink lines made with black pens. Twenty-one black gel and ballpoint pens from different brands and models were employed to prepare crossing combinations in both orders in white office paper. An initial pre-selection and extraction step using the Principal Components Analysis (PCA) scores plot arranged as histograms was necessary for extracting the inks spectra. Then, Partial Least Squares-Discriminant Analysis (PLS-DA) was applied for selection of the most important variables. Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) in the augmented form was performed using both the raw and the pre-processed spectra. However, the pre-processing of spectra resulted in incorrect identification of pixels in the inks distribution maps. The MCR-ALS results obtained using the raw spectra allowed the correct determination of the order of crossings in only one pair of gel-gel pen crossings. The remainder were either impossible to discriminate ink from paper or the skipping of one pen ink line led to incorrect determinations in one of the orders. In spite of the practical advantages of the HSI-NIR for document examination and the different chemometric approaches considered for surpassing some of the spectral limitations, the results obtained demonstrate the difficulties of using this technology for application in real forensic cases.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Multivariada / Espectroscopia de Luz Próxima ao Infravermelho / Tinta Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Forensic Sci Int Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Multivariada / Espectroscopia de Luz Próxima ao Infravermelho / Tinta Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Forensic Sci Int Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil