Your browser doesn't support javascript.
loading
Clinical application of a dried blood spot assay for sirolimus and everolimus in transplant patients.
Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; van den Berg, Aad P; de Groot, Marco R; Verschuuren, Erik A M; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J.
Afiliação
  • Veenhof H; Department of Clinical Pharmacy and Pharmacology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Koster RA; Department of Clinical Pharmacy and Pharmacology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Alffenaar JC; PRA Health Sciences, Bioanalytical Laboratory, Assen, The Netherlands.
  • van den Berg AP; Department of Clinical Pharmacy and Pharmacology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • de Groot MR; Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Verschuuren EAM; Department of Hematology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Berger SP; Department of Pulmonology and Tuberculosis, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Bakker SJL; Department of Internal Medicine, Division of Nephrology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Touw DJ; Department of Internal Medicine, Division of Nephrology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Clin Chem Lab Med ; 57(12): 1854-1862, 2019 Nov 26.
Article em En | MEDLINE | ID: mdl-30939110
ABSTRACT
Background Monitoring of immunosuppressive drugs such as everolimus and sirolimus is important in allograft rejection prevention in transplant patients. Dried blood spots (DBS) sampling gives patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. Methods A total of 39 sirolimus and 44 everolimus paired fingerprick DBS and whole blood (WB) samples were obtained from 60 adult transplant patients for method comparison using Passing-Bablok regression. Bias was assessed using Bland-Altman. Two validation limits were pre-defined limits of analytical acceptance were set at >67% of all paired samples within 20% of the mean of both samples and limits of clinical relevance were set in a multidisciplinary team at >80% of all paired samples within 15% of the mean of both samples. Results For both sirolimus and everolimus, Passing-Bablok regression showed no differences between WB and DBS with slopes of 0.86 (95% CI slope, 0.72-1.02) and 0.96 (95% CI 0.84-1.06), respectively. Only everolimus showed a significant constant bias of 4%. For both sirolimus and everolimus, limits of analytical acceptance were met (76.9% and 81.8%, respectively), but limits or clinical relevance were not met (77.3% and 61.5%, respectively). Conclusions Because pre-defined limits of clinical relevance were not met, this DBS sampling method for sirolimus and everolimus cannot replace WB sampling in our center at this time. However, if the clinical setting is compatible with less strict limits for clinical relevance, this DBS method is suitable for clinical application.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Medicamentos / Sirolimo / Everolimo Limite: Adult / Female / Humans / Male Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Medicamentos / Sirolimo / Everolimo Limite: Adult / Female / Humans / Male Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda