Design of an Optical Probe to Monitor Vaginal Hemodynamics during Sexual Arousal.
Jeong, Hyeryun; Seong, Myeongsu; Lee, Hyun-Suk; Park, Kwangsung; Moon, Sucbei; Kim, Jae Gwan.
Afiliação
  • Jeong H; Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea. ryun@gist.ac.kr.
  • Seong M; Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea. myeongsuseong@sjtu.edu.cn.
  • Lee HS; Department of Urology, Chonnam National University Medical School, Gwangju 61186, Korea. sys23@hanmail.net.
  • Park K; Department of Urology, Chonnam National University Medical School, Gwangju 61186, Korea. uropark@gmail.com.
  • Moon S; Department of Physics, Kookmin University, Seoul 02707, Korea. moons@kookmin.ac.kr.
  • Kim JG; Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea. jaekim@gist.ac.kr.
Sensors (Basel) ; 19(9)2019 May 08.
Article em En | MEDLINE | ID: mdl-31071987
ABSTRACT
An optical probe was developed to measure the change of oxy-hemoglobin (OHb), deoxy- hemoglobin (RHb), and total hemoglobin (THb) along with temperature from the vaginal wall of female rats. Apomorphine (APO, 80 µg/kg) was administered to elicit sexual arousal in female Sprague Dawley rats (SD, 180-200 g). The behavior changes caused by APO administration were checked before monitoring vaginal responses. The changes of oxy-, deoxy-, and total hemoglobin concentration and the temperature from the vaginal wall were monitored before, during, and after APO administration. Animals were under anesthesia during the measurement. After APO administration, the concentration of OHb (55 ± 29 µM/DPF), RHb (33 ± 25 µM/DPF), and THb (83 ± 59 µM/DPF) in the vaginal wall increased in a few min, while saline administration did not cause any significant change. In case of the vaginal temperature change, APO decreased the temperature slightly in the vaginal wall while saline administration did not show any temperature change in the vaginal wall. As the outcomes demonstrated, the developed probe can detect hemodynamic and temperature variation in the vaginal wall. The hemodynamic information acquired by the probe can be utilized to establish an objective and accurate standard of female sexual disorders.