Your browser doesn't support javascript.
loading
His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: Implications for pacemaker programming.
Jastrzebski, Marek; Moskal, Pawel; Bednarek, Agnieszka; Kielbasa, Grzegorz; Vijayaraman, Pugazhendhi; Czarnecka, Danuta.
Afiliação
  • Jastrzebski M; First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland. Electronic address: mcjastrz@cyf-kr.edu.pl.
  • Moskal P; First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
  • Bednarek A; First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
  • Kielbasa G; First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
  • Vijayaraman P; Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, Pennsylvania.
  • Czarnecka D; First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
Heart Rhythm ; 16(12): 1808-1816, 2019 12.
Article em En | MEDLINE | ID: mdl-31181375
BACKGROUND: Strength-duration curves for permanent His bundle (HB) pacing are potentially important for pacemaker programming. OBJECTIVES: We aimed to calculate strength-duration curves and chronaxies of the HB and of the adjacent right ventricular (RV) working myocardium and to analyze zones of selective HB capture and battery current drain when pacing at different pulse durations (PDs). METHODS: Consecutive patients with permanent HB pacing were studied. The RV and HB capture thresholds were assessed at several PDs. Battery current drain and zones of selective HB capture at PDs of 0.1, 0.2, 0.4, and 1.0 ms were determined. RESULTS: In the whole group (N = 127), the HB chronaxie was shorter than the RV chronaxie. This difference was driven by patients with selective HB pacing (HB chronaxie 0.47 ms vs RV chronaxie 0.79 ms). The strength-duration curve for the HB had a lower rheobase and its steep portion started at shorter PDs, thus creating wider distance-zone of programmable selective HB pacing-between the HB and RV strength-duration curves at shorter PDs. The battery current drain was lower with pacing at PDs of 0.1-0.4 ms vs 1.0 ms. Chronaxie-adjusted PDs offered the lowest current drain. CONCLUSION: For the first time, the strength-duration curves for permanent selective and nonselective HB pacing were determined. Selective HB capture and battery longevity can be promoted by shorter PDs (0.2 ms). Longer PDs (1.0 ms) offer greater safety margin for RV capture and may be preferable if simultaneous RV capture during HB pacing is desired.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Fascículo Atrioventricular / Estimulação Cardíaca Artificial / Eletrocardiografia / Doença do Sistema de Condução Cardíaco Limite: Humans Idioma: En Revista: Heart Rhythm Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Fascículo Atrioventricular / Estimulação Cardíaca Artificial / Eletrocardiografia / Doença do Sistema de Condução Cardíaco Limite: Humans Idioma: En Revista: Heart Rhythm Ano de publicação: 2019 Tipo de documento: Article