Your browser doesn't support javascript.
loading
Evaluation of a motion-robust 2D chemical shift-encoded technique for R2* and field map quantification in ferumoxytol-enhanced MRI of the placenta in pregnant rhesus macaques.
Zhu, Ante; Reeder, Scott B; Johnson, Kevin M; Nguyen, Sydney M; Golos, Thaddeus G; Shimakawa, Ann; Muehler, Matthias R; Francois, Christopher J; Bird, Ian M; Fain, Sean B; Shah, Dinesh M; Wieben, Oliver; Hernando, Diego.
Afiliação
  • Zhu A; Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
  • Reeder SB; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Johnson KM; Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
  • Nguyen SM; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Golos TG; Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
  • Shimakawa A; Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.
  • Muehler MR; Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA.
  • Francois CJ; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Bird IM; Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
  • Fain SB; Wisconsin National Primate Research Center, University of Wisconsin, Madison, Wisconsin, USA.
  • Shah DM; Department of Obstetrics and Gynecology, University of Wisconsin, Madison, Wisconsin, USA.
  • Wieben O; Wisconsin National Primate Research Center, University of Wisconsin, Madison, Wisconsin, USA.
  • Hernando D; Department of Obstetrics and Gynecology, University of Wisconsin, Madison, Wisconsin, USA.
J Magn Reson Imaging ; 51(2): 580-592, 2020 02.
Article em En | MEDLINE | ID: mdl-31276263
ABSTRACT

BACKGROUND:

3D chemical shift-encoded (CSE)-MRI techniques enable assessment of ferumoxytol concentration but are unreliable in the presence of motion.

PURPOSE:

To evaluate a motion-robust 2D-sequential CSE-MRI for R2* and B0 mapping in ferumoxytol-enhanced MRI of the placenta. STUDY TYPE Prospective. ANIMAL MODEL Pregnant rhesus macaques. FIELD STRENGTH/SEQUENCE 3.0T/CSE-MRI. ASSESSMENT 2D-sequential CSE-MRI was compared with 3D respiratory-gated CSE-MRI in placental imaging of 11 anesthetized animals at multiple timepoints before and after ferumoxytol administration, and in ferumoxytol phantoms (0 µg/mL-440 µg/mL). Motion artifacts of CSE-MRI in 10 pregnant women without ferumoxytol administration were assessed retrospectively by three blinded readers (4-point Likert scale). The repeatability of CSE-MRI in seven pregnant women was also prospectively studied. STATISTICAL TESTS Placental R2* and boundary B0 field measurements (ΔB0) were compared between 2D-sequential and 3D respiratory-gated CSE-MRI using linear regression and Bland-Altman analysis.

RESULTS:

In phantoms, a slope of 0.94 (r2 = 0.99, concordance correlation coefficient ρ = 0.99), and bias of -4.8 s-1 (limit of agreement [LOA], -41.4 s-1 , +31.8 s-1 ) in R2*, and a slope of 1.07 (r2 = 1.00, ρ = 0.99) and bias of 11.4 Hz (LOA -12.0 Hz, +34.8 Hz) in ΔB0 were obtained in 2D CSE-MRI compared with 3D CSE-MRI for reference R2* ≤390 s-1 . In animals, a slope of 0.92 (r2 = 0.97, ρ = 0.98) and bias of -2.2 s-1 (LOA -55.6 s-1 , +51.3 s-1 ) in R2*, and a slope of 1.05 (r2 = 0.95, ρ = 0.97) and bias of 0.4 Hz (LOA -9.0 Hz, +9.7 Hz) in ΔB0 were obtained. In humans, motion-impaired R2* maps in 3D CSE-MRI (Reader 1 1.8 ± 0.6, Reader 2 1.3 ± 0.7, Reader 3 1.9 ± 0.6), while 2D CSE-MRI was motion-free (Reader 1 2.9 ± 0.3, Reader 2 3.0 ± 0, Reader 3 3.0 ± 0). A mean difference of 0.66 s-1 and coefficient of repeatability of 9.48 s-1 for placental R2* were observed in the repeated 2D CSE-MRI. DATA

CONCLUSION:

2D-sequential CSE-MRI provides accurate R2* and B0 measurements in ferumoxytol-enhanced placental MRI of animals in the presence of respiratory motion, and motion-robustness in human placental imaging. LEVEL OF EVIDENCE 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2020;51580-592.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Óxido Ferroso-Férrico Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals / Female / Humans / Pregnancy Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Óxido Ferroso-Férrico Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals / Female / Humans / Pregnancy Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos