Your browser doesn't support javascript.
loading
Application of microchip and infrared thermography for monitoring body temperature of beef cattle kept on pasture.
Giro, Alessandro; Bernardi, Alberto Carlos de Campos; Barioni Junior, Waldomiro; Lemes, Amanda Prudêncio; Botta, Daniela; Romanello, Narian; Barreto, Andréa do Nascimento; Garcia, Alexandre Rossetto.
Afiliação
  • Giro A; Institute of Veterinary Medicine, Federal University of Pará, Castanhal, PA, Brazil.
  • Bernardi ACC; Brazilian Agricultural Research Corporation, Embrapa Southeast Livestock (CPPSE/Embrapa), São Carlos, SP, Brazil.
  • Barioni Junior W; Brazilian Agricultural Research Corporation, Embrapa Southeast Livestock (CPPSE/Embrapa), São Carlos, SP, Brazil.
  • Lemes AP; São Paulo State University "Júlio de Mesquita Filho", Jaboticabal, SP, Brazil.
  • Botta D; Institute of Veterinary Medicine, Federal University of Pará, Castanhal, PA, Brazil.
  • Romanello N; Institute of Veterinary Medicine, Federal University of Pará, Castanhal, PA, Brazil.
  • Barreto ADN; Institute of Veterinary Medicine, Federal University of Pará, Castanhal, PA, Brazil.
  • Garcia AR; Brazilian Agricultural Research Corporation, Embrapa Southeast Livestock (CPPSE/Embrapa), São Carlos, SP, Brazil. Electronic address: alexandre.garcia@embrapa.br.
J Therm Biol ; 84: 121-128, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31466744
ABSTRACT
The monitoring of body temperature is important for the diagnosis of the physiological state of the animal, being dependent on available methods and their applicability within production systems. This work evaluated techniques to monitor the body temperature of beef cattle kept on pasture and their ability to predict internal temperature. Twenty-three adult bovine females were monitored for six months, and collection data carried out in eleven campaigns (D0-D10) twelve days apart. During collections, the surface temperatures of ear base (ET, oC) and ocular globe (OGT, oC) were measured by infrared thermography, and the subcutaneous temperature (ST, oC) was measured with the use of transponder containing an implantable microchip. Rectal temperature (RT, oC) was considered as a reference for body temperature. Temperature and Humidity Index (THI), Black Globe Temperature and Humidity Index (BGHI) and Radiant Heat Load (RHL, W/m2) were calculated. ET (33.32 ±â€¯0.12 °C), ST (36.10 ±â€¯0.07 °C), OGT (37.40 ±â€¯0.06 °C) and RT (38.83 ±â€¯0.03 °C) differed significantly (P˂0.05). There was positive correlation of RT with OGT (r = 0.392), ET (r = 0.264) and ST (r = 0.236) (P˂0.05). Considering the bioclimatic indicators, the highest magnitude correlations were observed between ET and THI (r = 0.71), ET and BGHI (r = 0.65), and ET and RHL (r = 0.48). The use of microchip represented a practical method, but with limited predictability. On the other hand, infrared thermography proved to be safe and non-invasive, presenting greater precision for inference of internal body temperature. ET was more influenced by meteorological conditions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Bovinos / Termografia Limite: Animals Idioma: En Revista: J Therm Biol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Bovinos / Termografia Limite: Animals Idioma: En Revista: J Therm Biol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil