Your browser doesn't support javascript.
loading
Highly sensitive PDMS-filled Fabry-Perot interferometer temperature sensor based on the Vernier effect.
Appl Opt ; 58(18): 4858-4865, 2019 Jun 20.
Article em En | MEDLINE | ID: mdl-31503801
ABSTRACT
A highly sensitive temperature sensor is demonstrated experimentally, which is fabricated based on a Fabry-Perot interferometer (FPI) filled with polydimethylsiloxane (PDMS). The sensor's sensitivity is -0.653 nm/°C by utilizing the thermal expansion effect of PDMS, which has been greatly improved compared to that of the traditional FPI temperature sensor. Moreover, in order to further improve the sensitivity, a scheme where two parallel FPI structures are used to form the Vernier effect is proposed, which are a sensing FPI and reference FPI, respectively. Such a temperature sensor based on the FPI filled with PDMS and the Vernier effect exhibits a high temperature sensitivity of 17.758 nm/°C. Meanwhile, the proposed sensors show the advantages of high sensitivity, simplicity, and low cost.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Opt Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Opt Ano de publicação: 2019 Tipo de documento: Article