Your browser doesn't support javascript.
loading
Analytical considerations for postmortem metabolomics using GC-high-resolution MS.
Brockbals, Lana; Kraemer, Thomas; Steuer, Andrea E.
Afiliação
  • Brockbals L; Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zurich, Switzerland.
  • Kraemer T; Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zurich, Switzerland.
  • Steuer AE; Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zurich, Switzerland. andrea.steuer@irm.uzh.ch.
Anal Bioanal Chem ; 412(24): 6241-6255, 2020 Sep.
Article em En | MEDLINE | ID: mdl-31758199
ABSTRACT
Metabolomics studies that aim to qualitatively and quantitatively characterize the entirety of small endogenous biomolecules in an organism are widely conducted in the clinical setting. They also become more and more popular in the field of forensics (toxicology), e.g., to assist in postmortem investigations by objective postmortem interval estimation. However, other issues in postmortem toxicology, such as the phenomenon of (time-dependent) postmortem redistribution, have not yet been tackled by metabolomics studies. Hence, the aim of the current study was to develop an (un)targeted gas chromatography-high-resolution mass spectrometry-based method for endogenous metabolites as a tool for large-scale (un)targeted human postmortem metabolomics investigations (e.g., to objectively assess PMR) with thorough analytical evaluation of this method to ensure fitness-to-purpose in terms of reliability and robustness. This was achieved by using a targeted metabolite subset (n = 56) and a targeted processing workflow. Evaluation experiments have shown that using an artificial matrix (revised simulated body fluid (rSBF) + 5% bovine serum albumin (BSA)) for calibration purposes, all parameters lay within the scope of the method (sensitivity, selectivity, calibration model, accuracy, precision, processed sample stability, and extraction efficiency). When applying this method to large-scale studies, samples should be run in randomized order if analysis time is expected to exceed 18-24 h and potential biomarkers that are found with this method should be verified by a specialized, targeted method (e.g., by using standard addition in authentic matrix for quantification purposes). Overall, the current method can be successfully used for conduction of time-dependent postmortem metabolomics investigations. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mudanças Depois da Morte / Metabolômica / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mudanças Depois da Morte / Metabolômica / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Suíça