Your browser doesn't support javascript.
loading
Demonstration of SiO2/SiC based protective coating for dental ceramic prostheses.
Chen, Zhiting; Fares, Chaker; Elhassani, Randy; Ren, Fan; Kim, Mijin; Hsu, ShuMin; Clark, Arthur E; Esquivel-Upshaw, Josephine F.
Afiliação
  • Chen Z; University of Florida College of Engineering, Department of Chemical Engineering, Gainesville, FL.
  • Fares C; University of Florida College of Engineering, Department of Chemical Engineering, Gainesville, FL.
  • Elhassani R; University of Florida College of Engineering, Department of Chemical Engineering, Gainesville, FL.
  • Ren F; University of Florida College of Engineering, Department of Chemical Engineering, Gainesville, FL.
  • Kim M; University of Florida College of Dentistry, Department of Restorative Dental Sciences, Division of Prosthodontics Gainesville, FL.
  • Hsu S; University of Florida College of Dentistry, Department of Restorative Dental Sciences, Division of Prosthodontics Gainesville, FL.
  • Clark AE; University of Florida College of Dentistry, Department of Restorative Dental Sciences, Division of Prosthodontics Gainesville, FL.
  • Esquivel-Upshaw JF; University of Florida College of Dentistry, Department of Restorative Dental Sciences, Division of Prosthodontics Gainesville, FL.
J Am Ceram Soc ; 102(11): 6591-6599, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31819280
ABSTRACT
SiO2/SiC coatings were deposited onto ceramics disks using plasma enhanced chemical vapor deposition. The effects of deposition pressure and gas-flow ratio on the refractive index, extinction coefficient, and SiC composition were studied. For the highest studied SiH4 to CH4 gas-flow ratio of 1.5, the refractive index increased by 17% from 2.53 (at the wavelength of 845 nm) to 2.96 (at the wavelength of 400 nm). For the lowest studied SiH4 to CH4 gas-flow ratio of 0.5, the refractive index only increased by 4% from 2.11 (at the wavelength of 845 nm) to 2.20 (at the wavelength of 400 nm). At higher deposition pressures, the variation in refractive index of the SiC coatings was significantly lower showing a slight increase from 1.93 (at a wavelength of 845 nm) to 1.96 at a wavelength of 400 nm. Except for the case of a low SiH4 to CH4 gas-flow ratio of 0.5, for light with wavelengths ≤ 650 nm, the extinction coefficient of the SiC coatings increased significantly. Light with a wavelength > 650 nm had an extinction coefficient near 0 in all cases. After annealing the sample at 400°C for 4 hours, hydrogen-related bonds broke and the stress of the film was reduced from -245 to -71 MPa. By utilizing different thicknesses of SiC, the full standard dental shade guide was matched with the ΔE of each coated disk being less than 3.3 compared to the shade guide.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Ceram Soc Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Ceram Soc Ano de publicação: 2019 Tipo de documento: Article