Your browser doesn't support javascript.
loading
Rapid and quantitative detection of urinary Cyfra21-1 using fluorescent nanosphere-based immunochromatographic test strip for diagnosis and prognostic monitoring of bladder cancer.
Lei, Qifang; Zhao, Linlin; Ye, Shuixian; Sun, Yue; Xie, Fangjie; Zhang, Hong; Zhou, Fangjian; Wu, Song.
Afiliação
  • Lei Q; Third Affiliated Hospital of Shenzhen University, Shenzhen, Guangdong, China.
  • Zhao L; Institute of Urinary Surgery, Shenzhen University, Shenzhen, Guangdong, China.
  • Ye S; Shenzhen Following Precision Medical Research Institute, Shenzhen, Guangdong, China.
  • Sun Y; Advanced Institute for Medical Sciences, Dalian Medical University, Dalian, Liaoning, China.
  • Xie F; Third Affiliated Hospital of Shenzhen University, Shenzhen, Guangdong, China.
  • Zhang H; Hongqi Hospital, Mudanjiang Medical College, Mudanjiang, Heilongjiang, China.
  • Zhou F; Shenzhen Following Precision Medical Research Institute, Shenzhen, Guangdong, China.
  • Wu S; Third Affiliated Hospital of Shenzhen University, Shenzhen, Guangdong, China.
Artif Cells Nanomed Biotechnol ; 47(1): 4266-4272, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31842631
ABSTRACT
Bladder cancer is a common malignant tumour with high recurrence rate. Cytokeratin 19 fragments (Cyfra21-1) in urine has been regarded as a promising biomarker for the prognosis and diagnosis of bladder cancer due to the relevance of its high urinary level to the bladder cancer patients. However, currently detection methods of Cyfra21-1 have their limits, such as complicated steps, limited sensitivity or unsatisfying specificity. In this study, we developed a novel time-resolved fluoroimmuno test strip by using europium chelate microparticle (Eu-CM). Detection was performed in simple steps by carrying drops of sample into the well of the test strip, waiting for 15 min and inserting the strip into a fluorescence strip reader for quantitation. The standard curve equation of the test strip was y = 0.0177x + 0.01 (R2 = .9993). In the analysis of human urine samples (n = 115), it demonstrated a good performance (accuracy CV < 10%, AUC 0.989). With the cut-off value of 81 ng/mL, the sensitivity and specificity for bladder cancer were 92.86 and 100%, respectively. In comparison to ELISA and electrochemiluminescence methods, the Eu-CM based time-resolved fluoroimmuno test strip provided a rapid, sensitive and reliable method for monitoring bladder cancer. It may be applied as a non-invasive approach for in point-of-care for bladder cancer detection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Bexiga Urinária / Cromatografia de Afinidade / Urinálise / Queratina-19 / Nanosferas / Corantes Fluorescentes / Antígenos de Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Cells Nanomed Biotechnol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Bexiga Urinária / Cromatografia de Afinidade / Urinálise / Queratina-19 / Nanosferas / Corantes Fluorescentes / Antígenos de Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Cells Nanomed Biotechnol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China