Your browser doesn't support javascript.
loading
Preparation of palladium/carbon dot composites as efficient peroxidase mimics for H2O2 and glucose assay.
Zhuo, Shujuan; Fang, Jing; Zhu, Changqing; Du, Jinyan.
Afiliação
  • Zhuo S; Anhui Laboratory of Molecule-Based Materials; Key Laboratory of Functional Molecular Solids, Ministry of Education; Anhui Key Laboratory of Chemo-Biosensing, School of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, Anhui, China. sjzhuo@mail.ahnu.edu.cn.
  • Fang J; Anhui Meijia New Materials Company Limited, Wuhu, 241000, Anhui, China. sjzhuo@mail.ahnu.edu.cn.
  • Zhu C; Anhui Laboratory of Molecule-Based Materials; Key Laboratory of Functional Molecular Solids, Ministry of Education; Anhui Key Laboratory of Chemo-Biosensing, School of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, Anhui, China.
  • Du J; Anhui Laboratory of Molecule-Based Materials; Key Laboratory of Functional Molecular Solids, Ministry of Education; Anhui Key Laboratory of Chemo-Biosensing, School of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, Anhui, China. zhucq@mail.ahnu.edu.cn.
Anal Bioanal Chem ; 412(4): 963-972, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31853600
ABSTRACT
In this study, palladium/carbon dot composites (Pd-CDs) were fabricated via a facial hydrothermal route using ethanediamine and palladium chloride dihydrate as precursors. The obtained Pd-CDs showed an excellent intrinsic peroxidase-like activity, which could catalyze the oxidization of 3,3'5,5'-tetramethylbenzidine with the assistance of hydrogen peroxide (H2O2) and thus resulted in color change, accompanied by an absorption peak which appeared at 652 nm. Such response is H2O2 concentration-dependent and allows for the assay of H2O2 in the range of 0.1 to 30 µM with a limit of detection of 0.03 µM. Simultaneously, by combination of enzymatic oxidation of glucose with glucose oxidase and Pd-CD catalytic reaction, a colorimetric sensing platform was also constructed for glucose detection with high selectivity and sensitivity (limit of detection as low as 0.2 µM). Additionally, the proposed method exhibited capability for determination of glucose in real samples (fruit juice) with satisfactory recovery (98.5-103%), indicating potential application prospects in biochemical analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Paládio / Carbono / Glucose / Peróxido de Hidrogênio Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Paládio / Carbono / Glucose / Peróxido de Hidrogênio Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China