Your browser doesn't support javascript.
loading
Mitochondrial respiration variability and simulations in human skeletal muscle: The Gene SMART study.
Jacques, Macsue; Kuang, Jujiao; Bishop, David J; Yan, Xu; Alvarez-Romero, Javier; Munson, Fiona; Garnham, Andrew; Papadimitriou, Ioannis; Voisin, Sarah; Eynon, Nir.
Afiliação
  • Jacques M; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Kuang J; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Bishop DJ; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Yan X; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Alvarez-Romero J; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Munson F; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Garnham A; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Papadimitriou I; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Voisin S; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
  • Eynon N; Institute for Health and Sport (iHeS), Victoria University, Melbourne, Victoria, Australia.
FASEB J ; 34(2): 2978-2986, 2020 02.
Article em En | MEDLINE | ID: mdl-31919888
Mitochondrial respiration using the oxygraph-2k respirometer (Oroboros) is widely used to estimate mitochondrial capacity in human skeletal muscle. Here, we measured mitochondrial respiration variability, in a relatively large sample, and for the first time, using statistical simulations, we provide the sample size required to detect meaningful respiration changes following lifestyle intervention. Muscle biopsies were taken from healthy, young men from the Gene SMART cohort, at multiple time points. We utilized samples for each measurement with two technical repeats using two respirometer chambers (n = 160 pairs of same muscle after removal of low-quality samples). We measured the Technical Error of measurement (TEM ) and the coefficient of variation (CV) for each mitochondrial complex. There was a high correlation between measurements from the two chambers (R > 0.7 P < .001) for all complexes, but the TEM was large (7.9-27 pmol s-1  mg-1 ; complex dependent), and the CV was >15% for all complexes. We performed statistical simulations of a range of effect sizes at 80% power and found that 75 participants (with duplicate measurements) are required to detect a 6% change in mitochondrial respiration after an intervention, while for interventions with 11% effect size, ~24 participants are sufficient. The high variability in respiration suggests that the typical sample sizes in exercise studies may not be sufficient to capture exercise-induced changes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Consumo de Oxigênio / Exercício Físico / Músculo Esquelético / Mitocôndrias Musculares Limite: Adult / Female / Humans / Male Idioma: En Revista: FASEB J Assunto da revista: BIOLOGIA / FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Consumo de Oxigênio / Exercício Físico / Músculo Esquelético / Mitocôndrias Musculares Limite: Adult / Female / Humans / Male Idioma: En Revista: FASEB J Assunto da revista: BIOLOGIA / FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Austrália