Real-time 4DMRI-based internal target volume definition for moving lung tumors.
Rabe, Moritz; Thieke, Christian; Düsberg, Mathias; Neppl, Sebastian; Gerum, Sabine; Reiner, Michael; Nicolay, Nils Henrik; Schlemmer, Heinz-Peter; Debus, Jürgen; Dinkel, Julien; Landry, Guillaume; Parodi, Katia; Belka, Claus; Kurz, Christopher; Kamp, Florian.
Afiliação
  • Rabe M; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Thieke C; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Düsberg M; Department of Radiation Oncology, Klinikum rechts der Isar, Technical University, Munich, 81675, Germany.
  • Neppl S; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Gerum S; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Reiner M; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Nicolay NH; Medical Center, University of Freiburg, Freiburg, 79106, Germany.
  • Schlemmer HP; Department of Radiology, German Cancer Research Center, Heidelberg, 69120, Germany.
  • Debus J; Department of Radiation Oncology, University Hospital of Heidelberg, Heidelberg, 69120, Germany.
  • Dinkel J; Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, 69120, Germany.
  • Landry G; Department of Radiology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Parodi K; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
  • Belka C; Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching, 85748, Germany.
  • Kurz C; Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching, 85748, Germany.
  • Kamp F; Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.
Med Phys ; 47(4): 1431-1442, 2020 Apr.
Article em En | MEDLINE | ID: mdl-31955430
ABSTRACT

PURPOSE:

In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient-specific ITV definition method based on real-time 4D magnetic resonance imaging (rt-4DMRI).

METHODS:

Three lung cancer patients underwent weekly rt-4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath-hold MR images and propagated to all rt-4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions ITVs encompassing all GTV positions over the complete (ITV 80 s ) or partial acquisition time ( ITV 10 s ), ITVs including only voxels with a GTV probability-of-presence (POP) of at least 5% ( ITV 5 % ) or 10% ( ITV 10 % ), and the mid-ventilation GTV position. Reference planning target volumes ( PTV r ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the PTV r with ITV n 5 % from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE ( PTV r ∩ ITV n 5 % )/ ITV n 5 % ] and precision [PRE ( PTV r ∩ ITV n 5 % )/ PTV r ] as surrogates for target coverage and normal tissue sparing.

RESULTS:

Patient-specific analysis yielded a high variance of the overlap values of PTV r 10 s , when different periods within the reference imaging session were sampled. The mid-ventilation-based PTVs were smaller than the ITV-based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid-ventilation PTV for one patient. In contrast, PTV r 5 % and PTV r 10 % showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes.

CONCLUSIONS:

The results indicate that rt-4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today's 4D-CT-based target definition concepts.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional / Radioterapia Guiada por Imagem / Neoplasias Pulmonares / Movimento Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional / Radioterapia Guiada por Imagem / Neoplasias Pulmonares / Movimento Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha