Your browser doesn't support javascript.
loading
Polysaccharide-enhanced ARGET ATRP signal amplification for ultrasensitive fluorescent detection of lung cancer CYFRA 21-1 DNA.
Wang, Xia; Zhang, Yawen; Zhao, Liying; Wang, Dazhong; Yang, Huaixia; Kong, Jinming.
Afiliação
  • Wang X; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450008, Henan, China.
  • Zhang Y; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450008, Henan, China.
  • Zhao L; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450008, Henan, China.
  • Wang D; People's Hospital of Zhengzhou, Zhengzhou, 450008, Henan, China. wdzlion_fox@163.com.
  • Yang H; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450008, Henan, China. yanghuaixia886@163.com.
  • Kong J; School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China. j.kong@njust.edu.cn.
Anal Bioanal Chem ; 412(11): 2413-2421, 2020 Apr.
Article em En | MEDLINE | ID: mdl-32047944
ABSTRACT
An ultrasensitive fluorescence biosensor for detecting cytokeratin fragment antigen 21-1 (CYFRA 21-1) DNA of non-small cell lung carcinoma (NSCLC) is designed using polysaccharide and activator regenerated by electron transfer atom transfer radical polymerization (ARGET ATRP) signal amplification strategy. Thiolated peptide nucleic acid (PNA) is fixed on magnetic nanoparticles (MNPs) by a cross-linking agent and hybridized with CYFRA 21-1 DNA. Hyaluronic acid (HA) is linked to PNA/tDNA heteroduplexes in the form of carboxy-Zr4+-phosphate. Subsequently, multiple 2-bromo-2-methylpropionic acid (BMP) molecules are linked with HA to initiate ARGET ATRP reaction. Finally, a large number of fluorescein o-acrylate (FA) monomers are polymerized on the macro-initiators, and the fluorescence signal is significantly amplified. Under optimal conditions, this biosensor shows a significant linear correlation between the fluorescence intensity and logarithm of CYFRA 21-1 DNA concentration (0.1 fM to 0.1 nM), and the limit of detection is as low as 78 aM. Furthermore, the sensor has a good ability to detect CYFRA 21-1 DNA in serum samples and to recognize mismatched bases. It suggests that the strategy has broad application in early diagnosis by virtue of its high sensitivity and selectivity. Graphical abstract A novel and highly sensitive fluorescence biosensor for quantitatively detecting CYFRA 21-1 DNA via dual signal amplification of hyaluronic acid and ARGET ATRP reaction was developed. This proposed method has a low detection limit, wide detection range, high selectivity, and strong anti-interference.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / DNA / Técnicas Biossensoriais / Carcinoma Pulmonar de Células não Pequenas / Queratina-19 / Neoplasias Pulmonares / Antígenos de Neoplasias Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / DNA / Técnicas Biossensoriais / Carcinoma Pulmonar de Células não Pequenas / Queratina-19 / Neoplasias Pulmonares / Antígenos de Neoplasias Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China