Your browser doesn't support javascript.
loading
Online Correction Method for the Registration Error between TSMFTIS Detector and Interferogram.
Cao, Jun; Yuan, Yan; Su, Lijuan; Zhu, Conghui; Yan, Qiangqiang.
Afiliação
  • Cao J; Key Laboratory of Precision Opto-mechatronics Technology Sponsored by Ministry of Education, School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China.
  • Yuan Y; Key Laboratory of Precision Opto-mechatronics Technology Sponsored by Ministry of Education, School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China.
  • Su L; Key Laboratory of Precision Opto-mechatronics Technology Sponsored by Ministry of Education, School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China.
  • Zhu C; Key Laboratory of Precision Opto-mechatronics Technology Sponsored by Ministry of Education, School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China.
  • Yan Q; Key Laboratory of Spectral Imaging Technology of Chinese Academy of Sciences, Xi'an 710119, China.
Sensors (Basel) ; 20(4)2020 Feb 21.
Article em En | MEDLINE | ID: mdl-32098251
ABSTRACT
Temporally-spatially modulated Fourier transform imaging spectrometers (TSMFTISs) provide high-throughout-type push-broom spectrometry with both temporal and spatial modulation features. The system requires strict registration between the detector and the interferogram. However, registration errors are unavoidable and directly change the corresponding optical path difference values of the interferogram. As a result, the interferogram should be corrected before restoring the spectrum. In order to obtain the correct optical path difference (OPD) values, an online registration error correction method based on robust least-square linear fitting is presented. The model of the registration error was constructed to analyze its effect on the reconstructed spectra. Fitting methods were used to obtain correct optical path difference information. Simulations based on the proposed method were performed to determine the influence of the registration error on the restored spectra and the effectiveness of the proposed correction method. The simulation results prove that the accuracy of the recovered spectrum can be improved after correcting the interferogram deviation caused by the registration error. The experimental data were also corrected using the proposed methods.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China