Your browser doesn't support javascript.
loading
A rapidly new-typed detection of norovirus based on F0F1-ATPase molecular motor biosensor.
Zhao, Zhuo; Zhang, Jie; Xu, Mei-Ling; Liu, Zhi-Peng; Wang, Hua; Liu, Ming; Yu, Yan-Yan; Sun, Li; Zhang, Hui; Wu, Hai-Yan.
Afiliação
  • Zhao Z; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Zhang J; Beijing Entry-Exit Inspection Quarantine Bureau, Beijing, 100-026 China.
  • Xu ML; Linyi Entry-Exit Inspection Quarantine Bureau, Linyi, 276-034 China.
  • Liu ZP; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Wang H; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Liu M; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Yu YY; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Sun L; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Zhang H; Technical Center for Safety of Industrial Products, Tianjin Entry-Exit Inspection Quarantine Bureau, Tianjin, 300-308 China.
  • Wu HY; 4Weifang people's hospital of high-tech industrial development zone, Weifang, 261-205 China.
Biotechnol Bioprocess Eng ; 21(1): 128-133, 2016.
Article em En | MEDLINE | ID: mdl-32218681
ABSTRACT
In order to adapt port rapid detection of food borne norovirus, presently we developed a new typed detection method based on F0F1-ATPase molecular motor biosensor. A specific probe was encompassed the conservative region of norovirus and F0F1-ATPase within chromatophore was constructed as a molecular motor biosensor through the "ε-subunit antibody-streptomycin-biotin-probe" system. Norovirus was captured based on probe-RNA specific binding. Our results demonstrated that the Limit of Quantification (LOQ) is 0.005 ng/mL for NV RNA and also demonstrated that this method possesses specificity and none cross-reaction for food borne virus. What's more, the experiment used this method could be accomplished in 1 h. We detected 10 samples by using this method and the results were consistent with RT-PCR results. Overall, based on F0F1-ATPase molecular motors biosensor system we firstly established a new typed detection method for norovirus detection and demonstrated that this method is sensitive and specific and can be used in the rapid detection for food borne virus.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biotechnol Bioprocess Eng Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biotechnol Bioprocess Eng Ano de publicação: 2016 Tipo de documento: Article