Your browser doesn't support javascript.
loading
An electropolymerized molecularly imprinted polymer for selective carnosine sensing with impedimetric capacity.
Wojnarowicz, Agnieszka; Sharma, Piyush Sindhu; Sosnowska, Marta; Lisowski, Wojciech; Huynh, Tan-Phat; Pszona, Maria; Borowicz, Pawel; D'Souza, Francis; Kutner, Wlodzimierz.
Afiliação
  • Wojnarowicz A; Institute of Physical Chemistry (IPC PAS), Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl wkutner@ichf.edu.pl.
J Mater Chem B ; 4(6): 1156-1165, 2016 Feb 14.
Article em En | MEDLINE | ID: mdl-32263008
ABSTRACT
A chemosensor with a molecularly imprinted polymer (MIP) film as the recognition unit selective to a carnosine biomarker was molecularly engineered, devised and fabricated. The molecular structure of the pre-polymerization complex of the carnosine template with the carboxy and 18-crown-6 ether derivatives of bis(2,2'-bithien-5-yl)methane functional monomers was thermodynamically optimized by density functional theory (DFT) at the B3LYP/6-31g(d) level. The calculated high negative Gibbs free energy change, ΔG = -227.4 kJ mol-1, indicated the formation of a very stable complex. The solution of this complex was prepared and used for deposition of the MIP films on a Pt disk electrode or an Au electrode of the quartz crystal resonator by potentiodynamic electropolymerization. Subsequently, the carnosine template was extracted from the MIPs with 0.1 M NaOH, as confirmed by the differential pulse voltammetry (DPV), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy measurements. For carnosine sensing, impedimetric capacity (IC) measurements were performed under flow-injection analysis (FIA) conditions resulting in the limit of detection of 20 µM (at S/N = 3). This limit implied the readiness of the chemosensor for carnosine determination in clinical samples. Due to multiple modes of carnosine binding to MIP recognition sites, the IC chemosensor was found to be more selective to carnosine than to its common interferences including anserine, carcinine and histidine. Advantageously, the imprinting factor, determined by piezoelectric microgravimetry (PM), was high equaling 14.9.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Mater Chem B Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Mater Chem B Ano de publicação: 2016 Tipo de documento: Article