Your browser doesn't support javascript.
loading
Evaluation of low-volume post-dilution online hemodiafiltration with Japanese high-performance hemodiafilters.
Sakurai, Kenji; Hosoya, Hiromi; Kurihara, Yoshitaka; Yamauchi, Fumi; Suzuki, Ayumi; Kurosawa, Kaori; Saito, Takeshi.
Afiliação
  • Sakurai K; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan. ssakurai@peach.ocn.ne.jp.
  • Hosoya H; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan.
  • Kurihara Y; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan.
  • Yamauchi F; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan.
  • Suzuki A; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan.
  • Kurosawa K; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan.
  • Saito T; Hashimoto Clinic, 3-21-5 Hashimoto Midori-ku, Sagamihara, Kanagawa, 252-0143, Japan. saito@hashicli.jp.
J Artif Organs ; 23(3): 234-239, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32266500
ABSTRACT

PURPOSE:

To assess the removal performance of low-volume post-hemodiafiltration (HDF) with Japanese hemodiafilters and the removal performance with 20 % reduction in the total dialysate flow rate (Qdtotal).

METHODS:

Subjects were 8 patients undergoing pre-HDF. Study 1 Post-HDF was performed at a blood flow rate (Qb) of 250 mL/min and a total volume of substitution fluid (Vs) of 12 L/session(s) for 4 hrs using Fineflux-210Seco (FIX), ABH-21PA (ABH), and NVF-21H (NVF). We assessed removal efficiency of small molecular solutes, low-molecular-weight-proteins and the amount of albumin loss. Study 2 Post-HDF was performed at Vs of 12 L/s under G-1, Qdtotal of 500 and Qb of 250 mL/min; G-2, Qdtotal of 400 and Qb of 250 mL/min; and G-3, Qdtotal of 400 and Qb of 300 mL/min. Removal efficiency was compared and analyzed between these conditions.

RESULTS:

Study 1 The results using FIX, ABH and NVF are shown in order. The Kt/V were 1.8, 1.9 and 1.8. The ß2-Microglobulin (MG) removal rate (RR) (%) were 81.2, 83.1 and 82.8, and the α1-MG RR were 37.4, 40.2 and 38.5, respectively. Study 2 The results in G-1, 2 and 3 are shown in order. The Kt/V and the RR of small solutes, were significantly higher in G-3. The ß2-MG RR (%) were 81.2, 80.1 and 81.0, and the α1-MG RR were 37.4, 37.5 and 38.0, respectively.

CONCLUSIONS:

Low-volume post-HDF performed at Qb of 250 mL/min with Japanese high-performance hemodiafilters exhibited favorable removal efficiency for all solutes. Even with 20 % reduction in Qdtotal, the removal performance was also favorable.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemodiafiltração / Falência Renal Crônica Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Artif Organs Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemodiafiltração / Falência Renal Crônica Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Artif Organs Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão