Your browser doesn't support javascript.
loading
Effect of Microphone Configuration and Sound Source Location on Speech Recognition for Adult Cochlear Implant Users with Current-Generation Sound Processors.
Dwyer, Robert T; Roberts, Jillian; Gifford, René H.
Afiliação
  • Dwyer RT; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Roberts J; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Gifford RH; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
J Am Acad Audiol ; 31(8): 578-589, 2020 09.
Article em En | MEDLINE | ID: mdl-32340055
ABSTRACT

BACKGROUND:

Microphone location has been shown to influence speech recognition with a microphone placed at the entrance to the ear canal yielding higher levels of speech recognition than top-of-the-pinna placement. Although this work is currently influencing cochlear implant programming practices, prior studies were completed with previous-generation microphone and sound processor technology. Consequently, the applicability of prior studies to current clinical practice is unclear.

PURPOSE:

To investigate how microphone location (e.g., at the entrance to the ear canal, at the top of the pinna), speech-source location, and configuration (e.g., omnidirectional, directional) influence speech recognition for adult CI recipients with the latest in sound processor technology. RESEARCH

DESIGN:

Single-center prospective study using a within-subjects, repeated-measures design. STUDY SAMPLE Eleven experienced adult Advanced Bionics cochlear implant recipients (five bilateral, six bimodal) using a Naída CI Q90 sound processor were recruited for this study. DATA COLLECTION AND

ANALYSIS:

Sentences were presented from a single loudspeaker at 65 dBA for source azimuths of 0°, 90°, or 270° with semidiffuse noise originating from the remaining loudspeakers in the R-SPACE array. Individualized signal-to-noise ratios were determined to obtain 50% correct in the unilateral cochlear implant condition with the signal at 0°. Performance was compared across the following microphone sources T-Mic 2, integrated processor microphone (formerly behind-the-ear mic), processor microphone + T-Mic 2, and two types of beamforming monaural, adaptive beamforming (UltraZoom) and binaural beamforming (StereoZoom). Repeated-measures analyses were completed for both speech recognition and microphone output for each microphone location and configuration as well as sound source location. A two-way analysis of variance using mic and azimuth as the independent variables and output for pink noise as the dependent variable was used to characterize the acoustic output characteristics of each microphone source.

RESULTS:

No significant differences in speech recognition across omnidirectional mic location at any source azimuth or listening condition were observed. Secondary findings were (1) omnidirectional microphone configurations afforded significantly higher speech recognition for conditions in which speech was directed to ± 90° (when compared with directional microphone configurations), (2) omnidirectional microphone output was significantly greater when the signal was presented off-axis, and (3) processor microphone output was significantly greater than T-Mic 2 when the sound originated from 0°, which contributed to better aided detection at 2 and 6 kHz with the processor microphone in this group.

CONCLUSIONS:

Unlike previous-generation microphones, we found no statistically significant effect of microphone location on speech recognition in noise from any source azimuth. Directional microphones significantly improved speech recognition in the most difficult listening environments.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Percepção da Fala / Implantes Cocleares / Implante Coclear Tipo de estudo: Observational_studies Limite: Adult / Humans Idioma: En Revista: J Am Acad Audiol Assunto da revista: AUDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Percepção da Fala / Implantes Cocleares / Implante Coclear Tipo de estudo: Observational_studies Limite: Adult / Humans Idioma: En Revista: J Am Acad Audiol Assunto da revista: AUDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article