Your browser doesn't support javascript.
loading
Effect of Pulse Energy, Pulse Frequency, and Tip Diameter on Intracanal Vaporized Bubble Kinetics and Apical Pressure During Laser-Activated Irrigation Using Er:YAG Laser.
Kouno, Akira; Watanabe, Satoshi; Hongo, Tomoyuki; Yao, Kanako; Satake, Kazuhisa; Okiji, Takashi.
Afiliação
  • Kouno A; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Watanabe S; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Hongo T; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Yao K; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Satake K; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Okiji T; Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
Photobiomodul Photomed Laser Surg ; 38(7): 431-437, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32364877
ABSTRACT

Objective:

ErYAG laser-activated irrigation (LAI) is an effective method of root canal cleaning, but irrigant extrusion from the apical foramen has been a concern. We aimed to analyze the effects of pulse energy, pulse frequency, and laser tip diameter on intracanal vapor bubble kinetics and periapical pressure generation during LAI with ErYAG laser.

Background:

Irrigant vapor bubble kinetics are one of indices of root canal cleaning efficacy. However, few studies have compared laser pulse conditions to vapor bubble kinetics, in relation to periapical pressure.

Methods:

A plastic root canal model (apical diameter 0.50 mm, 6% taper, 20 mm long) was filled with distilled water, and LAI with ErYAG laser (Erwin AdvErl Unit; 30, 50, or 70 mJ; 10, or 20 pulses per second; laser tip R200T or R600T) was performed with the end of the tip fixed at 15 mm from the root apex. The number, maximum diameter, and velocity of vapor bubbles were analyzed by high-speed video imaging. Pressure generated outside the apical foramen was measured with a pressure sensor.

Results:

Vapor bubble count and maximum diameter increased significantly with pulse energy, pulse frequency, and tip diameter. Vapor bubble velocity increased significantly with pulse frequency, but not with pulse energy or tip diameter. Periapical pressure increased significantly with pulse energy, pulse frequency, and tip diameter.

Conclusions:

The pulse frequency was the single factor that significantly affected all the examined parameters (the number, diameter, and velocity) of vapor bubble kinetics together with the periapical pressure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Preparo de Canal Radicular / Terapia com Luz de Baixa Intensidade / Lasers de Estado Sólido Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Photobiomodul Photomed Laser Surg Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Preparo de Canal Radicular / Terapia com Luz de Baixa Intensidade / Lasers de Estado Sólido Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Photobiomodul Photomed Laser Surg Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão