Your browser doesn't support javascript.
loading
The Cytotoxicity and Genotoxicity of Three Dental Universal Adhesives-An In Vitro Study.
Wawrzynkiewicz, Adam; Rozpedek-Kaminska, Wioletta; Galita, Grzegorz; Lukomska-Szymanska, Monika; Lapinska, Barbara; Sokolowski, Jerzy; Majsterek, Ireneusz.
Afiliação
  • Wawrzynkiewicz A; Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Rozpedek-Kaminska W; Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Galita G; Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Lukomska-Szymanska M; Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Lapinska B; Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Sokolowski J; Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland.
  • Majsterek I; Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland.
Int J Mol Sci ; 21(11)2020 May 31.
Article em En | MEDLINE | ID: mdl-32486393
ABSTRACT
Dental universal adhesives are considered an useful tool in modern dentistry as they can be used in different etching techniques, allow for simplified protocol and provide sufficient bond strength. However, there is still no consensus as to their toxicity towards pulp. Thus, the present study aimed to evaluate the cytotoxicity and genotoxicity of three universal adhesives OptiBond Universal, Prime&Bond Universal and Adhese in an in vitro experimental model, monocyte/macrophage cell line SC (ATCC CRL-9855). The cytotoxicity was measured by means of XTT assay, whereas the genotoxicity (comet assay) was evaluated based on the percentage of DNA present in the comet tail. Furthermore, the ability of the adhesives to induce apoptosis was analyzed using flow cytometry (FC) with the FITC annexin V/propidium iodide (PI) double staining. The analysis of the cell cycle progression was performed with FC using PI staining. OptiBond Universal presented significant, while Prime&Bond Universal and Adhese Universal had minimal cytotoxicity and genotoxicity towards human SC cells. Moreover, only OptiBond Universal increased the level of apoptosis in SC cell line. None of the adhesives showed significant cell cycle arrest, as revealed by FC analysis. Due to substantial differences in toxicity in in vitro studies of dental adhesives, there is a great need for further research in order to establish more reliable test protocols allowing for standardized methodology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Polimetacrílicos / Resinas Acrílicas / Bis-Fenol A-Glicidil Metacrilato / Cimentos de Resina / Cimentos Dentários Limite: Humans Idioma: En Revista: Int J Mol Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Polimetacrílicos / Resinas Acrílicas / Bis-Fenol A-Glicidil Metacrilato / Cimentos de Resina / Cimentos Dentários Limite: Humans Idioma: En Revista: Int J Mol Sci Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Polônia