Vertical Flow Assay for Inflammatory Biomarkers Based on Nanofluidic Channel Array and SERS Nanotags.
Chen, Ruipeng; Du, Xin; Cui, Yujun; Zhang, Xieyuan; Ge, Qinyu; Dong, Jian; Zhao, Xiangwei.
Afiliação
  • Chen R; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
  • Du X; National Demonstration Center for Experimental Biomedical Engineering Education, Southeast University, Nanjing, 210096, China.
  • Cui Y; Southeast University Shenzhen Research Institute, Shenzhen, 518000, China.
  • Zhang X; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
  • Ge Q; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
  • Dong J; National Demonstration Center for Experimental Biomedical Engineering Education, Southeast University, Nanjing, 210096, China.
  • Zhao X; Southeast University Shenzhen Research Institute, Shenzhen, 518000, China.
Small ; 16(32): e2002801, 2020 08.
Article em En | MEDLINE | ID: mdl-32567225
ABSTRACT
There is a great demand for the development of detection assays for inflammation infection diagnosis with high throughput and ultrasensitivity. Herein, a vertical flow assay system with functionalized nanoporous anodic aluminum oxide (AAO) as sensing membrane, and encoded core-shell surface enhanced Raman scattering (SERS) nanotags as labels for multiple inflammatory biomarkers detection is presented. A 2 × 2 test array on the porous AAO is developed and modified with multiple capture antibodies to capture inflammatory biomarkers from samples. Due to the high surface area to volume ratio of the AAO membrane, and its influence on plasmonic coupling, the electromagnetic field of the encoded core-shell SERS nanotags is enhanced. Detection limits of 53.4, 4.72, 48.3, and 7.53 fg mL-1 are realized for C reactive protein, interleukin-6, serum amyloid A, and procalcitonin, respectively, with a linear dynamic range spanning at least five orders of magnitude. In addition, the proposed method also shows acceptable accuracy and repeatability for the detection of clinical samples. Therefore, this approach is expected to be a powerful point of care testing tool for disease diagnosis in facility limited areas.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanopartículas Metálicas / Ouro Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China