Your browser doesn't support javascript.
loading
A Clinical Application Study of Mixed Reality Technology Assisted Lumbar Pedicle Screws Implantation.
Gu, Yue; Yao, Qingqiang; Xu, Yan; Zhang, Huikang; Wei, Peiran; Wang, Liming.
Afiliação
  • Gu Y; The Third Clinical Medical College, Nanjing Medical University, Nanjing, Jiangsu, China (mainland).
  • Yao Q; Department of Orthopedic, Nanjing First Hospital, Nanjing, Jiangsu, China (mainland).
  • Xu Y; Department of Orthopedic, Nanjing First Hospital, Nanjing, Jiangsu, China (mainland).
  • Zhang H; Digital Medicine Institute, Nanjing Medical University, Nanjing, Jiangsu, China (mainland).
  • Wei P; The Third Clinical Medical College, Nanjing Medical University, Nanjing, Jiangsu, China (mainland).
  • Wang L; Department of Orthopedic, Nanjing First Hospital, Nanjing, Jiangsu, China (mainland).
Med Sci Monit ; 26: e924982, 2020 Jul 10.
Article em En | MEDLINE | ID: mdl-32647106
BACKGROUND This was a prospective comparative study of mixed reality (MR) technology assisted lumbar pedicle screws placement and traditional lumbar pedicle screws placement. MATERIAL AND METHODS Fifty cases of lumbar pedicle screws placement were randomly divided into 2 groups: 25 cases with MR technology in group A, and 25 cases without MR technology in group B. All patients had their scores on the Oswestry disability index (ODI) of low back pain and the visual analog scale (VAS) of the affected lower limb recorded at pre-operation. Blood loss, operative duration, success rate of first penetration by tap, and number of times C-arm fluoroscopy was performed were recorded at intraoperation. The postoperative drainage was recorded. The ODI of low back pain and VAS of the affected lower limb were recorded at 1, 3, and 6 months after operation. RESULTS Group A had less bleeding, shorter operation time, higher success rate of first penetration by tap, and fewer times using C-arm fluoroscopy at intraoperation (P<0.05). There was significant difference in ODI scores and VAS scores at 1 mouth after operation (P<0.05). The postoperative drainage of group A was less than group B (P<0.05). The implantation accuracy of group A was higher than group B (P<0.05). The postoperative recovery rate of low back pain of group A was faster than group B (P<0.05). CONCLUSIONS The safety of spinal surgery and implantation accuracy of pedicle screw fixation system could be increased by MR technology.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Parafusos Pediculares / Vértebras Lombares Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Assunto da revista: MEDICINA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Parafusos Pediculares / Vértebras Lombares Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Assunto da revista: MEDICINA Ano de publicação: 2020 Tipo de documento: Article