Your browser doesn't support javascript.
loading
Transport and Electrochemical Interface Properties of Ionomers in Low-Pt Loading Catalyst Layers: Effect of Ionomer Equivalent Weight and Relative Humidity.
Poojary, Sushmit; Islam, Muhammad Naoshad; Shrivastava, Udit N; Roberts, Edward P L; Karan, Kunal.
Afiliação
  • Poojary S; Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • Islam MN; Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • Shrivastava UN; Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • Roberts EPL; Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
  • Karan K; Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
Molecules ; 25(15)2020 Jul 26.
Article em En | MEDLINE | ID: mdl-32722653
Catalyst layer (CL) ionomers control several transport and interfacial phenomena including long-range transport of protons, local transport of oxygen to Pt catalyst, effective utilization of Pt catalyst, electrochemical reaction kinetics and double-layer capacitance. In this work, the variation of these properties, as a function of humidity, for CLs made with two ionomers differing in side-chain length and equivalent weight, Nafion-1100 and Aquivion-825, was investigated. This is the first study to examine humidity-dependent oxygen reduction reaction (ORR) kinetics in-situ for CLs with different ionomers. A significant finding is the observation of higher ORR kinetic activity (A/cm2Pt) for the Aquivion-825 CL than for the Nafion-1100 CL. This is attributed to differences in the interfacial protonic concentrations at Pt/ionomer interface in the two CLs. The differences in Pt/ionomer interface is also noted in a higher local oxygen transport resistance for Aquivion-825 CLs compared to Nafion-1100 CLs, consistent with stronger interaction between ionomer and Pt for ionomer with more acid groups. Similar dependency on Pt utilization (ratio of electrochemically active area at any relative humidity (RH) to that at 100% RH) as a function of RH is observed for the two CLs. As expected, strong influence of humidity on proton conduction is observed. Amongst the two, the CL with high equivalent weight ionomer (Nafion-1100) exhibits higher conduction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Polímeros de Fluorcarboneto / Técnicas Eletroquímicas / Íons Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Polímeros de Fluorcarboneto / Técnicas Eletroquímicas / Íons Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá