Your browser doesn't support javascript.
loading
Short-term biological variation and Reference change values of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine and 8-oxo-7,8-dihydroguanosine.
Zhang, Ruiping; Yu, Songlin; Wang, Danchen; Yin, Yicong; Yu, Jialei; Cao, Yongtong; Qiu, Ling.
Afiliação
  • Zhang R; Department of Clinical Laboratory, China-Japan Friendship Hospital, Beijing, China.
  • Yu S; Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
  • Wang D; Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
  • Yin Y; Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
  • Yu J; Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
  • Cao Y; Department of Clinical Laboratory, China-Japan Friendship Hospital, Beijing, China.
  • Qiu L; Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
J Clin Lab Anal ; 34(12): e23522, 2020 Dec.
Article em En | MEDLINE | ID: mdl-32827234
ABSTRACT

AIM:

The DNA and RNA oxidative damage products urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-odGsn) and 8-oxo-7,8-dihydroguanosine (8-oGsn) have potential use in clinical practice. However, biological variation (BV) and reference change values (RCVs) have not been established. The aim of this study was to establish the short-term between-subject BV(CVG ), within-subject BV(CVI ), and RCVs for urinary 8-odGsn and 8-oGsn.

METHODS:

First-morning midstream urine specimens were collected from 20 apparently healthy subjects(ten males and ten females) on five consecutive days. 8-odGsn and 8-oGsn were measured using LC-MS/MS, while urine creatinine (U-Cr) was also measured to correct their results. A two-level nested ANOVA was used to estimate the CVI and CVG.

RESULTS:

The values of CVG for 8-odGsn, 8-odGsn/U-Cr, 8-oGsn, and 8-oGsn/U-Cr were 31.2%, 39.6%, 35.3%, and 28.8%, respectively, while CVI for them were 40.5%, 9.0%, 33.5%, and 12.1%, respectively. The RCVs for 8-odGsn, 8-odGsn/U-Cr, 8-oGsn, and 8-oGsn/U-Cr were 112.5%, 26.7%, 93.7%, and 36.5%, respectively.

CONCLUSION:

BV and RCVs were firstly established for 8-oxo-dGsn and 8-oGsn, and can be used in clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: 8-Hidroxi-2'-Desoxiguanosina / Guanosina Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: 8-Hidroxi-2'-Desoxiguanosina / Guanosina Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China