Your browser doesn't support javascript.
loading
Determination of optimum pixel size and slice thickness for tractography and ulnar nerve diffusion tensor imaging at the cubital tunnel using 3T MRI.
Park, Sun-Young; Koh, Sung Hye; Lee, In Jae; Lee, Kwanseop; Lee, Yul.
Afiliação
  • Park SY; Department of Radiology, 158781Hallym University Sacred Heart Hospital, Gyeonggi-do, Republic of Korea.
  • Koh SH; Department of Radiology, 158781Hallym University Sacred Heart Hospital, Gyeonggi-do, Republic of Korea.
  • Lee IJ; Department of Radiology, 158781Hallym University Sacred Heart Hospital, Gyeonggi-do, Republic of Korea.
  • Lee K; Department of Radiology, 158781Hallym University Sacred Heart Hospital, Gyeonggi-do, Republic of Korea.
  • Lee Y; Department of Radiology, 158781Hallym University Sacred Heart Hospital, Gyeonggi-do, Republic of Korea.
Acta Radiol ; 62(8): 1063-1071, 2021 Aug.
Article em En | MEDLINE | ID: mdl-32854528
ABSTRACT

BACKGROUND:

Small peripheral nerve tractography is challenging because of the trade-off among resolution, image acquisition time, and signal-to-noise ratio.

PURPOSE:

To optimize pixel size and slice thickness parameters for fiber tractography and diffusion tensor imaging (DTI) of the ulnar nerve at the cubital tunnel using 3T magnetic resonance imaging (MRI). MATERIAL AND

METHODS:

Fifteen healthy volunteers (mean age 30 ± 6.8 years) were recruited prospectively. Axial T2-weighted and DTI scans were acquired, covering the cubital tunnel, using different pixel sizes and slice thicknesses. Three-dimensional (3D) nerve tractography was evaluated for the median number and length of the reconstructed fiber tracts and visual score from 0 to 5. Two-dimensional (2D) cross-sectional DTI was evaluated for fractional anisotropy (FA) values throughout the length of the ulnar nerve.

RESULTS:

A pixel size of 1.3 mm2 revealed the highest number of reconstructed nerve fibers compared to that of 1.1 mm2 (P = 0.048), with a good visual score. A slice thickness of 4 mm had the highest number of reconstructed nerve fibers and visual score compared with other thicknesses (all P < 0.05). In 2D cross-sectional images, the median FA values were in the range of 0.40-0.63 at the proximal, central, and distal portions of the cubital tunnel. Inter-observer agreement for all parameters was good to excellent.

CONCLUSION:

For fiber tractography and DTI of the ulnar nerve at the cubital tunnel, optimal image quality was obtained using a 1.3-mm2 pixel size and 4-mm slice thickness under MR parameters of this study at 3T.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nervo Ulnar / Imagem de Tensor de Difusão Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nervo Ulnar / Imagem de Tensor de Difusão Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article